Step 12 

For  wet  cuts,  run  the  drive  motors  revolution  up  to  a  wire  speed  between  approx.  20  and 
30 m/sec. 

 

Step 13 

For dry cuts, choose great wire length and low wire speed.  

 

Step 14 

Choose the feed pressure so that there is no overload of the drive motor. The amperemeter 
should have a value between 25 and 30 ampere.  
 

Step 15 

Examine  the  wire  only  when  the  unit  is  standing  still  or  the  wire  speed  is  very  low  (2-3 
m/sec). 
 

Step 16 

When  the  wire  reaches  the  center  of  the  hollow  axe,  reposition  the  swivel  rollers  of  the 
guiding device inwards in cutting direction. Thus, the wire is captured at the cut end, and a 
damage of the hollow axes is avoided (see Pict. 14, page 24). 
 

Step 17 

When the cut is finished, stop the machine with the emergency-stop button 

 

(see p.16, Pict. 

13, pos. 4). Release feed tension only after the wire comes to a standstill.  

 

13  M

AINTENANCE AND SERVICE OF WIRE SAW  

WB12T 

 
Any maintenance and service works may only be done when the unit stands still. Disconnect 
the power supply to the system (put on/off button in 0 position and unplug the mains plug.  
 
The best maintenance activities are the daily removal of mud, dust and dirt.  
 
Discharging  condensation  water  at  the  wire  saw  system:  with  the  provided  key,  open  the 
drain  screw  under  pressure  at  the  back frame  end.  Leave  open  until  dry  air  passes  off  the 
tank. Then lock the valve again.  
 
Always use a hollow axe protection and replace if necessary. 

 

14  M

AINTENANCE AND SERVICE OF THE CONTROL PANEL 

 

 

14.1  Condensation water 

 

In the sight glass of the air regulation valve, condensation water accumulates continuously. It 
can  be  discharged  by  simple  (up-)pressing  the  hose  nipple  at  the  bottom  side  of  the  sight 
glass.  The  PVC  hose  must  be  connected  and  the  water  must  be  able  to  drain  off  to  the 
outside 

 

(see p.16, Pict. 13, pos. F and G)

.

 

 

14.2  Cleaning 

 

Keep the control panel clean and wipe it only with a dry or moist cloth. Never use a water-jet 
or high pressure cleaner.  

Summary of Contents for Braxx WB12T

Page 1: ...in Germany Lagerstrasse 6 Oberheinrieter Stra e 30 32 A 5071 Wals bei Salzburg D 74199 Unterheinriet Tel 43 0 662 42 42 48 Tel 49 0 7130 40095 0 Fax 43 0 662 42 42 48 20 Fax 49 0 7130 40095 20 e Mail...

Page 2: ...sures at the installation place 9 6 10 Emergency measures 10 7 Safety Equipment 10 8 Mounting the System 10 8 1 Positioning 10 8 2 Electrical connection 10 8 3 Compressed air supply pneumatic unit 11...

Page 3: ...ions completely Please direct inquiries to the manufacturer or an authorized dealer Please observe our safety features and safety precautions which are highlighted by a at the respective locations in...

Page 4: ...achine Guideline 89 392 CEE i d F 91 368 CEE Guideline Electromagnetic Compatibility EMC 89 336 EG i d F 93 31 CEE Low Voltage Guideline 73 23 CEE The following harmonized standards were applied EN 29...

Page 5: ...ervance will void the warranty and any product liability 4 SPECIFICATIONS Rated voltage 230 400 V Current consumption 63 A 3PH N PE Power 32 kW water cooled Frequency 1000 Hz Revolutions 0 2200 min 1...

Page 6: ...e p 16 electric drive motor dismountable by quick separation system Pict 1 pos 2 see p 16 dismountable saw head with special drive gear offset rolley two counterrotating guide rollers and two swivel r...

Page 7: ...vide fresh air for the user for his protection mainly when dry cutting Spare wire lengtsh can be covered by safety guards However staying in the direction of the alignment or in the danger area Pict 3...

Page 8: ...n 6 4 Emissions The A rated equivalent continuous sound pressure level of this system is lower than 75 dbA thus no ear protection is needed Hence this wire saw is especially suitable for the use in co...

Page 9: ...e user s safety The user has to ensure that only authorized personnel operate the machine He is responsible towards third parties in the working area of the unit 6 8 Personal safety measures Use safet...

Page 10: ...against any displacement The equipment for wire guiding guiding system 3 wheel or compatible existing roller systems has to be fixed securely onto the workpiece with an achor screw For safety reasons...

Page 11: ...ic unit is low maintenance as the settings are adjusted automatically neither pre nor readjustments are necessary It is soil resisting due to the extra wiper rings at the guiding shaft The pneumatic u...

Page 12: ...his ensures that the wire can not skip off the rollers when the unit starts With these measures an optimal function of the wire saw system WB12T can be ensured Non observance risks damages at the wire...

Page 13: ...ep 6 Align the swivel rollers at the cut and the swivel rollers at the machine universal guiding system exactly Step 7 If the material which is to be cut has sharp edges they have to be smoothed off a...

Page 14: ...SERVICE OF WIRE SAW WB12T Any maintenance and service works may only be done when the unit stands still Disconnect the power supply to the system put on off button in 0 position and unplug the mains p...

Page 15: ...nufactured by EDT EURODIMA GMBH Any guarantees and warranty become void if machines or machine parts have been opened This warranty is valid on condition that the machine is used handled maintained an...

Page 16: ...ES Pict 1 System demounted Parts which are marked with new design look differently having a new design and improved functionalities Pict 2 System with protection cover Hollow axle cover Pos 1 Removabl...

Page 17: ...WB12T 17 Pict 3 danger zone...

Page 18: ...WB12T 18 Pict 4 wire guiding layout...

Page 19: ...WB12T 19 Pict 5 Views and dimensioning...

Page 20: ...WB12T 20 Pict 6 Views without protection coverings Hollow axle protection...

Page 21: ...WB12T 21 Pict 7 swivel pulley Pict 8 notching pulley Pict 9 Wire guiding device Pict 10 Plunge saw device Hollow axle protection...

Page 22: ...WB12T 22 Pict 11 pipe cutting device Pict 12 Mounting at a vertical cut...

Page 23: ...Pos H Pressure release valve at power failure relieve pressure Pos 1 Button motor ON Pos 2 Control lamp green ready for use Pos 3 Control lamp blue wire storage full Pos 4 Emergency stop button motor...

Page 24: ...WB12T 24 Pict 14 Pulley setting For finishing the cut reset the wire pulleys...

Reviews: