background image

 

 

User Manual 

 

 

 

 

typhoon SB201 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

EDT EURODIMA GMBH 

 

Diamond Technologies 

 

 

Lagerstrasse 6 

 

A-5071 Wals bei Salzburg 

 

Tel.: +43 (0) 662 / 42 42 48 

 

Fax: +43 (0) 662 / 42 42 48-20

 

  

e-Mail: 

[email protected]

  

 

www.eurodima.com

  

Summary of Contents for Braxx typhoon SB201

Page 1: ...User Manual typhoon SB201 EDT EURODIMA GMBH Diamond Technologies Lagerstrasse 6 A 5071 Wals bei Salzburg Tel 43 0 662 42 42 48 Fax 43 0 662 42 42 48 20 e Mail office eurodima com www eurodima com...

Page 2: ...res 8 7 5 Wall saw setup 9 7 6 Mounting the rails 10 7 7 Guide rail extension 11 7 8 Mounting the wall saw 11 7 9 Mount the stirrup underpinning 11 7 10 Assembly changing the saw blade 12 7 11 Mountin...

Page 3: ...y Please direct inquiries to the manufacturer or an authorized dealer Please observe our safety features and safety precautions which are highlighted by that sign at the respective locations in the ma...

Page 4: ...01 DIN EN 50144 1 1999 DIN EN 50144 2 2000 b with regard to electromagnetic compatibility Interference emission DIN EN 55014 1 2000 A1 2001 VDE 0875 part 14 1 DIN EN 61000 3 2 2000 DIN EN 61000 3 3 19...

Page 5: ...le motor The motor rpm is progressively adjustable with the BC201 control unit The swivel arm and the advance are regulated by the remote control on the control unit Horizontal and vertical wall cuts...

Page 6: ...lugging always pull on the plug never on the cable 5 2 Securing the building site The building site must be secured in coordination with the contractor The general public must not be allowed on the bu...

Page 7: ...not operate the machine Unless under the supervision of qualified personnel for training purposes The owner of the machine must provide the operator with the user manual and ensure that he has read an...

Page 8: ...s Energy supply Ensure that the power supply at the construction site is properly fuse protected 7 2 Extension cords Use only approved extension cords of adequate ladder cross section Eurostandard plu...

Page 9: ...omponents main saw head with integrated advance and swivel motor drive motor with safety coupling blade cover with stirrup guide rail with fastening brackets and limit stop BC201 or BC321 control unit...

Page 10: ...e diameter 15 mm or M12 masonry anchors hole diameter 20 mm The following parts are required M12 drive in anchors hole diameter 15 or 16 mm Or M12 masonry anchors hole diameter 20 mm Washers according...

Page 11: ...e motor on the guide rail lock on and secure Free from play locking There must be no play and no jamming between the rollers and the guide rails in order to achieve a straight and clean cut This is ac...

Page 12: ...atch the centering collar of the blade flange Do not use saw blades with worn holes Damaged flanges must be replaced A locking mechanism protects the flange cover from rotating and the fixing screw fr...

Page 13: ...color friction points marks deformation and cracks 7 11 Mounting the blade guard Only operate the wall saw with the blade cover attached The size of the blade cover must match the diameter of the saw...

Page 14: ...tion are located on the rating plate and in the user manual Always mind the correct sequence At start up first connect the motor cable and the remote control then connect the mains plug Please note Af...

Page 15: ...er to keep electrical connections clean The plug connections of the motor have protection caps Bent or broken connection pins must be immediately replaced with new ones Electric repairs may only be ca...

Page 16: ...ture of the cooling water and the water pressure Ambient temperature max 45 C At temperatures under 5 C the cooling water must be preheated or antifreeze must be added Always blow out the machine dang...

Page 17: ...re described in the user manual of the braxx control BC201 or BC321 remote control with emergency stop 4 way gear lever motor on off 3x LED control green yellow red potentiometer eye to hook in for ab...

Page 18: ...bs on the remote control and the control unit must be set to zero Only operate the wall saw when the blade cover is attached Do not touch any movable parts of the machine during start up risk of injur...

Page 19: ...oncrete with a large proportion of reinforcing steel In case of critical or hazardous situations press the EMERGENCY STOP button immediately 8 5 Practical tips Observe the saw blade s direction of mot...

Page 20: ...e motor must continue to be cooled for at least 10 minutes after finishing a cut or prior to an extended interruption in cutting otherwise the motor will be damaged The cooling water must be drained f...

Page 21: ...not use a steam jet cleaner Keep the rail clean If the concrete sludge is difficult to remove clean the rail and the toothed rack with a brass wire brush The bolts of the toothed rack must be checked...

Page 22: ...cations and changes to the machine as well as non observance of the operating instructions void the manufacturer s liability for resulting damage We only warrant error free operation for original repl...

Reviews: