A)  Power Switch

B)  Pump Switch

H)  Pump Indicator Light

D) SH230

     Sponge

     Holder

I) AC Receptacle

A) Activates System Power.

B) Turns on and shuts off Pump.

C) Tool Holder minimized heat dissipation when Tool is not in use.

D) Includes (1) LN230 Liner, (1) RS199 Cleaning Sponge and RS243 

Leveling Pad. 

E) Filters air coming in to the Pump. Acts as silencer

F)  Lights when power is on.

G) Regulates air flow to Tool. (connect to FA069)

H) Lights when Pump is running.

I)   Can accomodate 2 more 120V soldering Tools.

SPECIFICATIONS:

• 120 V, 60 Hz, 150 W

• Weight: 4.6 lbs. (2.09 kgs.)

• Temperature range: 400

0

F - 800

0

F (205

0

C - 425

0

C)

• Temperature regulation: ± 6

0

F (±3

0

C)

• Voltage leakage from tip to ground less than 2 MV

• Tip to ground resistance less than 2 ohm

• Maximum pressure: 18 psi.

• UL listed

Static Safe

G) Air Control 

       Valve

E) AF110 Low Static

     Air Filter

FEATURES

C)  PD525 Pod

F)   Power Indicator 

      Light

E) AF110 Low Static

     Air Filter

PS542 ATMO-

SCOPE

®

 

Power Supply

Fuse, 6.3A

All manuals and user guides at all-guides.com

Summary of Contents for 1036 atmoscope

Page 1: ...MOSCOPE self contained SMD HOT AIR WORK STATION COMPLIES WITH MIL S 45743E MIL STD 2000 DOD STD 2000 1B WS6536E AND ESD SPEC DOD STD 1686 DOD HDBK 263 MADE IN THE U S A All manuals and user guides at...

Page 2: ...o Tool connect to FA069 H Lights when Pump is running I Can accomodate 2 more 120V soldering Tools SPECIFICATIONS 120 V 60 Hz 150 W Weight 4 6 lbs 2 09 kgs Temperature range 4000 F 8000 F 2050 C 4250...

Page 3: ...Pump CAUTION DO NOT POINT TOOL AT ANYONE OR ANYWHERE HOT AIR WILL BURN The 3 very important factors involved when working with the Hot Air Station are amount of air output temperature setting and type...

Page 4: ...pressure 5 Direct hot air towards the connection until solder melts Using SMD helpers will make your job easier 1 Turn Tip counter clockwise by using a WT618 Tip Wrench set of 2 the other is to hold t...

Page 5: ...ct hot air on the leads and allow solder to reflow Release SMD when solder solidifies METHOD 2 RECOMMENDED FOR LEADLESS CHIP CARRIERS WS630 METHOD 3 Dual Flow Tip 1 Use a Dual Flow Tip whose width com...

Page 6: ...12 in 1 8 in 3 2 mm 20 in 13 64 in 5 1 mm 28 in 17 64 in 7 0 mm 35 in 23 64 in 8 9 mm Description L W Application 020 in 5 mm Fan Tips use a wide air flow enough to cover one whole side of the SMD Tur...

Page 7: ...all connections are properly installed Replace cracked hoses and O rings b Replace with clean filters c FA069 should be connected to Air Control Valve d Clean Air passages along RS321 and Tip e Clean...

Page 8: ...Air Tool 1 7 RS321 Retaining Sleeve for FA069 Hot Air Tool 1 9 LT428 LONER S M D Hot Air Turbo Flow Tip 1 10 SR028 Power Cord 3 Prong 120 VAC 1 11 SR029 Boot for Power Cord 1 12 SR030 Clear Handle for...

Page 9: ...1 4 5 10 28 11 23 30 31 32 33 24 20 19 3 2 A B C D 27 22A 8 25 26 12 24 24 20 19 21 29 22 16 34 7 34 13 6 9 15 17 18 16 14 16 16 17 18 22B 15 All manuals and user guides at all guides com...

Page 10: ...SR719 Air Flow Control Valve 1 15 SR439 Holder Clip for AF110 4 16 AF110 In Line Filter includes items 17 18 2 17 AF627 Felt Filter set of 10 2 18 AF040 Foam Filter set of 10 2 19 SR802 LED Yellow 1...

Page 11: ...ncludes TI680 SDS100 FX635 5 Insert the hot air tip inside the TPL09 1 place the center of the thermocouple wire of the SDS100 inside the slot of TPL09 1 loca tor Use only CLEAN thermocouple wires 6 T...

Page 12: ...RED BY U S AND FOREIGN PATENTS AND PENDING APPLICATIONS DESIGN COLOR AND MATERIALS SUBJECT TO CHANGE WITHOUT NOTICE TIP STYLE ON SOLDERING DESOLDERING AND HOT AIR TOOLS MAY VARY PRINTED IN U S A Copyr...

Reviews: