
98
TP-00347-01
Chapter 6: Troubleshooting
DF
Warning event!
See section below
E0
Incompatible magazine detected
Check type of lowest left
magazine
Magazine type not supported.
E2
Unsupported hardware (library
Extender) detected - library
firmware upgrade required
Library Extender was installed
without upgrading the library
firmware. Upgrade library code
to revision which supports this
feature
EB
Power supply health check failed
due to a power supply failure.
Please contact service.
Contact technical support
Power supply probably defective.
F0
Drive Over temperature
Condition
Check ambient temperature
conditions and check all fans,
after several occurrences contact
technical support
Drive probably defective.
The sub code indicates which
drive is affected
Example:
Sub code 01: drive #1
F1
Drive Communication Error,
library controller has lost
communication to drive
Retry operation; if not successful
contact technical support
Communication cable between
drive and drive sled controller
defective.
The sub code indicates which
drive is affected
Drive sled controller defective.
Example:
Check cabling drive sled
controller- backplane
Sub code 01: drive #1
Check cabling backplane library
controller
Drive defect / check drive
F2
Drive sled not present
Retry operation; if not successful
contact technical support
Drive probably defective.
The sub code indicates which
drive sled is affected
Check if drive sled is completely
inserted
Example:
Drive sled controller defect.
Sub code 01: drive sled #1
Drive defective.
F3
Drive Hardware Error
Cycle Power; after several
occurrences contact technical
support
Drive probably defective.
The sub code indicates which
drive is affected
Example:
Sub code 01: drive #1
F4
Drive Load Timeout
Retry operation; if not successful
contact technical support
Drive probably defective.
Drive has run in a timeout while
loading a tape
Drive leader bent.
The sub code indicates which
drive is affected
Drive initialize repeatedly.
Drive defect (no function).
Error
Code
Description
User Action
Critical Component Status
Summary of Contents for 24Q
Page 1: ...24Q Ark Tape Library 48Q Ark Tape Library Setup and User s Guide ...
Page 37: ...TP 00347 01 37 Operator Control Panel OCP Main Menu Main Menu ...
Page 38: ...38 TP 00347 01 Chapter 4 Operation Information Menu Information Menu 1 of 2 ...
Page 39: ...TP 00347 01 39 Operator Control Panel OCP Information Menu 2 of 2 ...
Page 40: ...40 TP 00347 01 Chapter 4 Operation Commands Menu Commands Menu ...
Page 41: ...TP 00347 01 41 Operator Control Panel OCP Configuration Menu Configuration Menu ...
Page 42: ...42 TP 00347 01 Chapter 4 Operation Service Menu Service Menu 1 of 2 ...
Page 43: ...TP 00347 01 43 Operator Control Panel OCP Service Menu 2 of 2 ...
Page 70: ...70 TP 00347 01 Chapter 4 Operation ...
Page 106: ...106 TP 00347 01 Chapter 7 Specifications ...
Page 110: ...110 TP 00347 01 Chapter 8 Regulatory Information ...
Page 111: ......
Page 112: ...TP 00347 01 ...