16
Before using this unit
Use these feet when not mounted on a system rack or whenever necessary at any
other installation sites.
Remove the backing from the adhesive side of the skids, and stick them on the
bottom of the unit as shown below.
fig.set-01.eps
If you are planning to mount this unit on a system rack, be sure to follow these notes
to cool down the unit efficiently.
• Install at a site with sufficient ventilation.
• Do not mount the unit in an enclosed system rack. The unit may draw in the
warmed up air inside the rack, and cannot cool down efficiently.
• Should a multiple number of units be mounted together, be sure to keep enough
space to expel heated air from the rack and that the unit does not draw the heated
air back in again. If the rear of the rack cannot be kept open, construct an air vent in
the region where the warmed air tends to accumulate, usually the upper part of the
rear of the rack, or build in a ventilator.
• If you are using the unit mounted inside a portable rack, uncover both front and
rear sides of the rack and make sure that both ends have enough clearance.
• If an error message warns of overheating, immediate countermeasures are needed
to cool down the unit. Recheck the installation state of the unit or rack following
the notes above.
* While mounting the unit on the system rack, be careful not to get your fingers pinched.
* For further instructions regarding the installation, refer also to
About installation
Attaching the rubber feet (supplied)
System rack installation (heat releasing notes)