- 21
-
ENGLISH
CHARACTERISTICS
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualifi ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
The above data are indicative and are those resulting during certifi cation on the part of the notifi ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES
• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on defi ned parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insuffi cient for it to function correctly.
THERMO TECHNICAL CHARACTERISTICS according to EN 14785
Nominal power
Reduced power
Heat input (burnt)
9
2,5
kW
Heat output
8
2,4
kW
Yield / Effi ciency
93
95,1
%
Emissions CO 13% O2
0,013
0,059
%
Fume temperature
129
63
°C
Fuel consumption
1,9
0,5
kg/h
Hopper capacity
24
kg
Autonomy
11
42
hours
Heatable volume *
210
m
3
Smoke outlet pipe diameter (male)
80
mm
Air intake pipe diameter (male)
40
mm
Weight including packaging
200
kg
TECHNICAL DATA FOR THE DIMENSIONING OF THE FLUE
Nominal power
Reduced power
Heat output
8
2,4
kW
Temperature of fumes on exit from the discharge pipe
200
110
°C
Minimum draught
12
10
Pa
Fume fl ow capacity
5,8
3,2
g/s
Classifi cation of combustion chamber according to DIBt
FB 22 FC
52x
-
*
The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
ELECTRICAL CHARACTERISTICS
Power supply
230 Vac +/- 10% 50 Hz
On/off switch
Yes
Average power consumption
100
W
Power consumption during ignition
400
W
Remote control frequency
Radio waves 2,4 GHz
Protection on mains power supply* (see page 20)
T2A, 250 Vac, 5x20 Fuse
Protection on electronic circuit board
T2A, 250 Vac, 5x20 Fuse
Summary of Contents for LOU
Page 122: ...122...
Page 125: ...125 cod 941103 11 13 B w w w e d i l k a m i n c o m...