GFCI MAINTENANCE:
Although the GFCI function works on its own, it is nec-
essary to test for proper function of your GFCI periodi-
cally. To do this:
1. Plug your equipment to an appropriate wall plug.
2. Press the “TEST” button on the GFCI panel on the
cord.
3. Turn on the switches for “PUMP” and “VACUUM”
(located on the switch panel on the front of the ma-
chine).
If your motors turn on, then the GFCI is NOT working
properly- do not use the equipment until this function
has been repaired. Take the machine to an authorized
repair location.
If neither motor powers on after pressing the “TEST”
button then the GFCI is working properly.
Press the “RESET” button on the GFCI and the EN-
DEAVOR will be fully functional again.
NOTE: THE GFCI MUST BE RESET ANY TIME
THE CORD IS UNPLUGGED. WHEN THE GFCI IS
OPERATING PROPERLY, THE RED INDICATOR
LIGHT WILL BE ON.
CORD STORAGE:
While not in use, store cords in a clean dry area. Wind
cord carefully to prevent kinking. Cord should be com-
pletely unwound during operation.
CORD SAFETY
• Do not leave appliance when plugged in. Unplug
from outlet when not in use and before servicing
• Do not use with damaged cord or plug. If appliance
is not working as it should, has been dropped, dam-
aged, left outdoors, or dropped into water, return to
service center for inspection and repair.
• Do not pull or carry by cord, use cord as handle,
close a door on cord, or pull cord around sharp edges
or corners. Do not run over cord.
• Keep cord away from heated surfaces.
• Do not unplug by pulling cord. To unplug, grasp the
plug, not the cord.
• Do not handle plug or appliance with wet hands.
• This equipment should be stored indoors and not
exposed to rain.
MAINTENANCE OF THE ENDEAVOR:
The ENDEAVOR has been engineered and built to re-
quire minimum maintenance. However, careful attention
to these maintenance instructions will help extend the
life of your equipment.
DAILY:
• Keep the ENDEAVOR clean inside and out.
• Pour clean hot water (MAX 130°F/ 57°C) into the
solution tank of your ENDEAVOR extractor. Turn
the pump on and flush the entire system through the
spray nozzles for 1 minute to prevent chemical build-
up.
• Run the vacuum motor for 30 seconds before putting
away the ENDEAVOR.
• Rinse out the Recovery tank.
• Clean the vacuum intake pre-filter bag and the pum-
pout filter.
MONTHLY:
• Use an extractor flushing agent through the ma-
chine’s plumbing to dissolve mineral and chemical
build up.
• Quick disconnects, wheels, casters, and regulators
can be lubricated with an all-purpose silicone lubri-
cant spray.
• Check and clean the filters in the solution tank.
PUMP WEAR AND TEAR MAINTENANCE:
After 500 hours, replace the following pump head com-
ponents:
• KIT A, PLUNGER AND SEALS: PART #G13333-1
• KIT B, VALVE SET: PART #G13333-2
• CAM BEARING: PART #G13682
After 1500 hours, replace the following pump head com-
ponents:
• KIT A, PLUNGER AND SEALS: PART #G13333-1
• CAM BEARING: PART #G13682
After 3000 hours, replace the following pump head com-
ponents:
• KIT B, VALVE SET: PART #G13333-2
Contact EDIC for PUMP maintenance instructions.