UNPACKING YOUR NEW ENDEAVOR:

When your equipment is delivered, check the carton 

carefully for signs of rough handling. If the ENDEAVOR 

is damaged, notify the carrier immediately and request 

an inspection. Be sure to keep the carton, packing in-

serts, packing lists and carrier’s receipt until the inspec-

tor has verified your claim.

EDIC’s liability ceases when the carrier picks up the 

shipment. However, our customer service staff will be 

happy to furnish any information needed in connection 

with the claim and will attempt to expedite a resolution.

 

PLEASE READ BEFORE OPERATING YOUR 

NEW ENDEAVOR:

Read the manual carefully and completely before at-

tempting to operate the unit. This manual has important 

information for the use and safe operation of the ma-

chine. Keep this manual handy at all times.

This equipment has been engineered and manufactured 

to provide excellent performance and service. To ensure 

that your equipment will continue to perform as intend-

ed:

•  Maintain equipment regularly- following the sug-

gested maintenance schedule provided.

•  Use only original EDIC parts when servicing.

•  Operate equipment with care.

All information and specifications printed in the man-

ual are current at the time of printing; however because 

of EDIC’s policy of continual product development, we 

reserve the right to make changes at any time without 

notice.

 

FAILURE TO COMPLY WITH THE FOLLOWING 

WARNINGS AND INSTRUCTIONS MAY POSE A 

HAZARD AND WILL VOID THE WARRANTY.

WARNING:

 

•  This is not a toy. Keep away from children.

•  Always read and understand your chemical’s MSDS (Ma-

terial Safety Data Sheet) before use.

•  This extractor is not designed to handle or use combus-

tible/volatile substances such as gasoline or kerosene, in, 

on, or near the equipment. The use of such materials will 

cause extreme hazardous condition.

•  Make sure the extractor has all water filters in place.

•  Do not allow high pressure spray stream to remain in one 

fixed location as surface damage may occur.

•  Check that all spray nozzles are securely fastened. Loose 

nozzles could be ejected from equipment at high speeds.

•  Prevent burns by wearing gloves or using a barrier to 

remove hot quick disconnects.

•  Use caution with ejected liquid or chemicals. High pres-

sures and temperatures could be hazardous to nearby peo-

ple or surroundings.

•  All servicing of EDIC equipment should be performed 

only by EDIC authorized service centers.

•  Do not use replacement parts other than those specified in 

the parts list. Equipment performance could be affected if 

substitutions are made. Use of no-EDIC parts will void the 

warranty.

 

•  When using an extension cord, use only a 3-prong conduc-

tor grounding cord-12 gauge wire or heavier. Do not use 

extension cords longer than 25FT.

•  To avoid electric shock, do not expose the unit to rain 

or snow. Store indoors in a heated location only. Do not 

expose machine to freezing temperatures.

•  Do not use the machine for dry vacuuming.

•  Use defoamer at all times to prevent damage to the vacu-

um motor.

•  Do not use water in excess of 130°F (54°C) in the solution 

tank

•  To prevent seal damage and chemical build-up to the 

pump system, run clean water through the solution lines 

after each day’s use.

•  Use only commercially available carpet cleaning solutions 

and defoamer intended for use with machines of this type. 

Do not use dyes, bleaches, ammonia, or other additives. 

•  The use of powdered cleaning solution, if not diluted 

properly, may result in damage to the pump. Powdered 

chemical is not recommended. If powdered chemicals 

are used, premix in a separate container before placing in 

the solution tank. Any damage resulting from powdered 

chemical will void the warranty.

•  Do not pull machine by the power cord. Always unplug by 

grabbing the plug and pulling, do not unplug by pulling 

the power cord.

•  Periodically inspect cord for damage. Do not use damaged 

cords. Connect only to properly grounded outlets.

•  Keep hair, fingers, loose clothing, and body parts away 

from moving parts and openings.

•      Turn off all controls before disconnecting machine
•  Do not use without vacuum pre-filter bag in place.

3

Summary of Contents for Endeavor 9000I-HSH

Page 1: ...sing Michigan 48906 Fax 517 484 9836 Email CustomerService Michco com Website www Michco Com Order Parts online at www Michco Com Directly to Parts Service By Email CustomerService Michco com By Fax 5...

Page 2: ...w ENDEAVOR 9000I HSH MULTI PURPOSE EXTRACTOR OWNER S OPERATOR S MANUAL PROUDLY DESIGNED AND MANUFACTURED BY Revision 1 6 5 17 For commercial use only EDIC USA COM...

Page 3: ...UTO DUMP PRIMING THE PUMP ADJUSTING PUMP PRESSURE OPERATING INSTRUCTIONS FOR HEATER CLEANING CARPET CLEANING TILE AND GROUT MOUNTING THE 991RS SYSTEM OPTIONAL SETUP OF 991RS SYSTEM OPTIONAL USING A 90...

Page 4: ...ation as surface damage may occur Check that all spray nozzles are securely fastened Loose nozzles could be ejected from equipment at high speeds Prevent burns by wearing gloves or using a barrier to...

Page 5: ...more than 25 feet 7 6 m long GFCI CORD FUNCTION The ENDEAVOR s power cords are equipped with a built in GFCI Ground Fault Circuit Interrupter The GFCI function is automatic and will not be active unde...

Page 6: ...or corners Do not run over cord Keep cord away from heated surfaces Do not unplug by pulling cord To unplug grasp the plug not the cord Do not handle plug or appliance with wet hands This equipment s...

Page 7: ...ank and access point 6 Accessory management system Secures 1 carpet wand or 1 REVOLUTION wand to the ENDEAVOR 7 Grab handle and clam shell screw access point 8 Rear caster wheels Allow the machine to...

Page 8: ...Pressure regulator Allows presure to be adjusted by turning clockwise raising pressure or counter clockwise reducing pressure 7 Solution line Q D Allows solution line to be connected to the machine 8...

Page 9: ...plugged into two separate circuits the circuit locator confirmation light will turn on The confirmation light is marked CT and is located on the control panel See 4 on page 7 1 Connect both power cord...

Page 10: ...nd after every job VACUUM INTAKE FILTER AND VACUUM SHUT OFF The vacuum intake filter houses the float ball which is in place to shut off airflow to the vacuum motor when there is too much fluid in the...

Page 11: ...to start recovering water turn on the PUMPOUT switch 9 on page 5 5 The pump can be left on throughout your job so long as small amounts of water are flowing through the pump Turn off the PUMPOUT swit...

Page 12: ...r cords are plugged into two sepa rate circuits When the pressure on the machine has been reduced to below 500PSI To use the heater 1 Connect Solution line to 7 on page 7 Connect vac uum hose to 8 on...

Page 13: ...o ensure your vacuum motor does not take in fluid HOW TO SETUP THE ENDEAVOR FOR TILE AND GROUT 1 Plug in power cords as per instructions on page 8 2 Make sure you are on 2 circuits 3 Connect your solu...

Page 14: ...connect on the main body of the 991RS STEP 3 The intake bottle caps and the clear hoses that are at tached to them are designed to be removed and inter changed by way of a quick release system When y...

Page 15: ...nsert on the intake bottle cap barb and install a metering tip by threading it in a clock wise motion STEP 6 Once the tip has been installed push the clear hose back into place over the hose barb STEP...

Page 16: ...angle of spray from a concen trated stream to a wider pattern by rotating the spray collar clockwise or counter clockwise Note Chemical cannot be applied in the high pressure rinse mode TOUCH LESS HAR...

Page 17: ...s you make your way out of the room 10 Allow the chemical time to dwell according to the chemical manufacturers recommendations 11 You may use a brush to agitate particularly soiled areas 12 When you...

Page 18: ...17 40 17 20 16 10 36 13 12 19 15 42 41 6 1 4 43 34 5 3 21 2 30 38 25 7 28 9 14 39 37 11 27 22 33 24 29 31 26 35 18 32 23 11 11 8 39 8 14 3 9000I HSH ENDEAVOR SOLUTION TANK EXPLODED VIEW 5 5 2017...

Page 19: ...1 HEX 3 17 C13559 HEX BOLT 5 16 X 5 1 2 SS 2 18 C13666 NUT KEP 8 32 SS 5 19 C13740 LOCKWASHER 10 SPLIT 3 20 C13859 WASHER NEOPRENE BONDED 4 21 C13871 WASHER 11 16 SS 3 22 C13939 NUT KEP 4 40 SS 1 23 C...

Page 20: ...7 67 24 69 13 14 4 32 12 26 23 19 41 29 18 27 38 30 28 44 17 40 39 55 57 31 59 37 58 75 64 34 52 73 80 65 43 66 63 45 46 20 76 78 25 35 62 7 16 48 54 15 6 53 8 10 2 42 56 43 74 34 2 9 2 17 17 24 2 9 8...

Page 21: ...LE 1 15 B02211 1 SWITCH ROCKER GREEN LIT 4 16 B11756 INDICATOR LIGHT 1 17 C00233 1 WASHER FLAT 1 4 SS 16 18 C00273 1 4 20 NYLON INSERT LOCKNUT 1 19 C00328 112 SCREW 10 32 X 1 1 2 PH 1 20 C02231 8 WASH...

Page 22: ...0621 VAC HOSE 2 ID BLACK 23 L 1 59 J00639 CLAMP HOSE 2 0 4 60 J00651 HOSE CLAMP 25 TO 625 4 61 J11154 SOL HOSE 100 PSI WIRE 375 ID X 42 L 1 62 J11154 1 SOL HOSE 25 ID X 30 L 1 63 J11508 SCREW CLAMP 6...

Page 23: ...77 16 10 33 6 65 5 7 9 80 73 74 3 4 76 78 61 75 60 59 46 11 55 66 36 44 51 27 79 56 64 34 2 1 58 45 21 19 40 85 20 26 86 72 23 37 63 28 53 57 69 49 71 70 47 54 12 17 35 50 39 32 22 30 76 21 19 19 30...

Page 24: ...RRENT SENSOR 1 18 B13851 DIN RAIL 1 19 C00233 WASHER FLAT USS 1 4 15 20 C00233 1 WASHER FLAT 1 4 SS 8 21 C00254 LOCKWASHER 1 4 SPLIT 6 22 C00256 LOCKWASHER 10 EXT STAR 2 23 C00273 1 4 20 NYLON INSERT...

Page 25: ...ALL MOUNT GAS SPRING 1 60 D13436 BALL SOCKET 10MM 1 61 D13437 EYELET GAS SPRING 1 62 D13729 CAP POWER ENTRY 2 63 D14057 PLATE WASHER 1 64 E00449 GROMMET 1 65 E13246 WASHER WATER HOSE 2 66 E13440 GROMM...

Reviews: