ORACLE SERIES 2E, 2EC, 4E, 4EC, 4H
Operations Manual
Eberle Design Inc.
Page 16
To temporarily turn off the heater function before the 60 minute time-out occurs, press the
MENU button Up (
Back
position) while in the main display level. The heater function and
backlight will be turned off until the next switch activation. This over-ride function is not
available on the Oracle 4H model.
3.7.5 OPTIONS MENU ITEM (ORACLE EC SERIES)
For the Oracle 2EC and 4EC models, selecting the Option menu item provides access to
the Probe Gap and Stream control items.
3.7.5.1 PROBE GAP MENU ITEM
The
Probe Gap Between Vehicles
item allows a user to specify the minimum gap between
vehicles passing through the detection zone only when operating in the Probe Mode. The
entry range is 150 milliseconds to 500 milliseconds. This setting helps to optimize the
distinction between closely spaced vehicles and large trucks.
3.7.5.2 STREAM MENU ITEM (ORACLE ECX SERIES)
For the Oracle 2ECX and 4ECX models this option enables a serial communication
function to stream signature data to a recording station.
Warning
The LCD Heater function consumes approximately 3 watts for an Oracle 2E,
and 6 watts for an Oracle 4E. Activating the LCD Heater function on multiple
Oracle units in the cabinet simultaneously can add a significant amount of
load current being required from the Cabinet Power Supply.