2010ECL-NYC SERIES SIGNAL MONITOR
OPERATIONS MANUAL
Eberle Design Inc.
Page 37
Pin #
Function
I/O
7
CTS
-
8
RTS
O
9
NC
-
RTS is provided for compatibility with Data Terminal Equipment (DTE device) control signals.
9.4.1 EIA-232 CABLE TO A PC
A typical cable assembly for a DB-9 connector on the PC would be a straight through
connection as follows:
PC DB-9
Monitor DB-9
RX pin 2
connect to
TX pin 2
TX pin 3
connect to
RX pin 3
GND pin 5
connect to
GND pin 5
A typical cable assembly for a DB-25 connector on the PC would be as follows:
PC DB-25
Monitor DB-9
RX pin 3
connect to
TX pin 2
TX pin 2
connect to
RX pin 3
GND pin 7
connect to
GND pin 5
9.4.2 EIA-232 CABLE TO A 170 CONTROLLER UNIT
A typical cable assembly for 170 CU connector would be as follows:
170
Monitor DB-9
RX pin L
connect to
TX pin 2
TX pin K
connect to
RX pin 3
GND pin N
connect to
GND pin 5
DCD pin H should be connected to +5 pin D on the Controller Unit connector.
CTS pin M should be connected to RTS pin J on the Controller Unit connector.
9.5 ETHERNET LAN PORT
The Ethernet port must be configured with specific network parameters such as an IP
address. The network port parameters are set or changed using the EDI
ECcom
Signal
Monitor Communications software. See the "
EDI ECcom Software Operations Manual
" for
details on the SETUP / COMM PORT / SETTINGS /
Search
function. Additional information
on the Ethernet port capabilities can be found in the “
Ethernet Quick Start Operation
Manual
”, pn888-1000-101.
The factory default network settings are: IP Address = 192.168.1.100 and Subnet Mask =
255.255.255.0
9.5.1 ETHERNET LAN CABLE
The LAN cable required is a typical Cat-5 network cable using the 8 pin RJ-45 connector. If
the connection is from the monitor to a switch or hub, a standard LAN cable is needed. If the
connection is from the monitor directly to a network adaptor (PC), a cross-over or patch cable
is needed.
9.6 16-CHANNEL PROGRAM CARD DIAGRAM