Page 1: ...Edgewater EdgeProtect 7300 System Hardware Guide April 2013 7300 000 001B ...
Page 2: ...ritten permission of Edgewater Networks Inc Under the law reproducing includes translating into another language or format As between the parties Edgewater Networks Inc retains title to and ownership of all proprietary rights with respect to the software contained within its products The software is protected by United States copyright laws and international treaty provision Therefore you must tre...
Page 3: ...s front and back physical connections Symbol Function Color Signal A Power Status Green Off No Power the system is off On Power is good the system is on Data Status Red Off No data access to the IDE drive On Data is being written to the IDE drive ...
Page 4: ...nterface must not be on the same network as the WAN or LAN subnets This network cannot be within a subnet contained in a Route statement F Port 2 WAN interface 1 x 10 100 1000 Mbps RJ 45 Ethernet port for connectivity to the WAN or Internet network connectivity Default IP none G Port 1 LAN interface 1 x 10 100 1000 Mbps RJ 45 Ethernet port for LAN network connectivity Default IP 192 168 1 1 H USB ...
Page 5: ...adapter and switch are not receiving power 2 No connection between both ends of the network cable check cable replace cable Green or other Flashing The adapter is sending and receiving network data The frequency of the flashing varies with the amount of data being transferred Speed Yellow On ACK LINK LED must be on This LED will show the system operating at 1000 Mbps Green On ACK LINK LED must be ...
Page 6: ...m 1 73 1U Weight 12 75 lbs Power 100 240v VAC auto selecting 50 to 60 Hz with 200W MAX AC Input BTU h 682 Warranty 3 Years Environmental Requirement Operating Temperature 0 to 40 C Relative Humidity 10 to 90 Certifications RoHS 2 0 Compliant WEEE Compliant Safety UL cUL LVD Gost R Mexico CoC UL AR Emissions FCC Part 15 Class A ICES 003 VCCI Class A KCC CCC C tick BSMI ANATEL Immunity CE MTBF 7300 ...
Page 7: ... 7300 Mount the completed assembly into your 19 equipment rack Connecting the Power and Cables The 7300 comes with an AC power cord for connecting the unit to the AC outlet Warning Always connect the AC power cord to an AC outlet suitable for the power supply per the Power specifications listed in this document in order to reduce the risk of damage to the 7300 power supply Connect one end of the A...
Page 8: ...ove figures 3 Connect a computer using an IP address of 192 168 1 2 and subnet mask of 255 255 255 0 to Port 1 shown as G in the above figures with either a Ethernet switch or a Ethernet cable wired directly to the computer 4 Launch a Web browser on the computer and enter the http 192 168 1 1 or https 192 168 1 1 8443 Press Return The main configuration menu appears enter the username root and the...
Page 9: ...sly approved by Edgewater Networks Inc could void the user s authority to operate this equipment The socket outlet to which this apparatus is connected must be installed near the equipment and must always be readily accessible Part 15 FCC Rules This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference an...
Page 10: ... telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed 5 The REN of this equipment is either marked on the unit or included in the new style USA FCC registration number In the case that the REN is included in the FCC number the user should use the following key to det...
Page 11: ...7300 Hardware Guide 10 Korea China ...
Page 12: ...EF Deutsch German Hiermit erklärt Edgewater dass sich das Gerät EdgeProtect 7300 in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999 5 EG befindet Eesti Estonian Käesolevaga kinnitab Edgewater seadme EdgeProtect 7300 vastavust direktiivi 1999 5 EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele Es...
Page 13: ... andere relevante bepalingen van richtlijn 1999 5 EG Malti Maltese Hawnhekk Edgewater jiddikjara li dan EdgeProtect 7300 jikkonforma mal ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid Dirrettiva 1999 5 EC Magyar Hungarian Alulírott Edgewater nyilatkozom hogy a EdgeProtect 7300 megfelel a vonatkozó alapvetõ követelményeknek és az 1999 5 EC irányelv egyéb elõírásainak Polski Po...
Page 14: ...iden ehtojen mukainen Svenska Swedish Härmed intygar Edgewater att denna EdgeProtect 7300 står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Íslenska Icelandic Hér með lýsir Edgewater yfir því að EdgeProtect 7300 er í samræmi við grunnkröfur og aðrar kröfur sem gerðar eru í tilskipun 1999 5 EC Norsk Norwegian Edgewater erklær...
Page 15: ...to End user the purchase price paid for the Product Advance replacement units are shipped same business day for next day delivery within the US when hardware failure is determined by 1pm PST Failed components must be returned to Edgewater within 14 days or End user will be charged for new product purchase Restriction of Hazardous Substances Directive RoHS Edgewater Networks products are RoHS compl...