background image

 

EdgeConnect  
2402PoE LF Managed 
Ethernet Switch 

Installation Guide 
 

Version 1.0 

 

 

 

U.S. Headquarters: 

2895 Northwestern Parkway 
Santa Clara, CA 95051 

Phone: +1 (408) 351-7200 
Fax: +1 (408) 727-6430 

www.edgewaternetworks.com 

EWN005-05-D001

Summary of Contents for EdgeConnect 2402PoE

Page 1: ...2402PoE LF Managed Ethernet Switch Installation Guide Version 1 0 U S Headquarters 2895 Northwestern Parkway Santa Clara CA 95051 Phone 1 408 351 7200 Fax 1 408 727 6430 www edgewaternetworks com EWN...

Page 2: ...nd of implied or express warranty of non infringement of the implied warranties of merchantability or fitness for a particular purpose WARRANTY AND REPAIR SERVICE CENTER Interwork Technologies Bill Du...

Page 3: ...pressly approved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mb...

Page 4: ...e fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995...

Page 5: ...also operates under SELV conditions France and Peru only This unit cannot be powered from IT supplies If your supplies are of IT type this unit must be powered by 230 V 2P T via an isolation transfor...

Page 6: ...power plug to a valid earth ground line to prevent electrical hazards Warning This switch uses lasers to transmit signals over fiber optic cable The lasers are compliant with the requirements of a Cl...

Page 7: ...dards End of Product Life Span This product is manufactured in such away as to allow for the recovery and disposal of all included electrical components once the product has reached the end of its lif...

Page 8: ...6 Expandability 1 7 Performance 1 7 Management 1 7 2 Network Planning 2 1 Introduction to Switching 2 1 Application Examples 2 2 Supplying PoE 2 2 Collapsed Backbone 2 3 Network Aggregation Plan 2 4...

Page 9: ...y Rules 4 8 1000BASE T Cable Requirements 4 8 1000 Mbps Gigabit Ethernet Collision Domain 4 9 100 Mbps Fast Ethernet Collision Domain 4 10 10 Mbps Ethernet Collision Domain 4 10 Cable Labeling and Con...

Page 10: ...TABLE OF CONTENTS xvii Management Features C 3 Standards C 3 Compliances C 3 Glossary Index...

Page 11: ...Length 4 9 Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length 4 9 Table 4 4 Maximum 1000BASE ZX Gigabit Ethernet Cable Length 4 9 Table 4 5 Maximum Fast Ethernet Cable Length 4 10 Table 4 6 M...

Page 12: ...6 Figure 3 1 RJ 45 Connections 3 2 Figure 3 2 Attaching the Brackets 3 5 Figure 3 3 Installing the Switch in a Rack 3 5 Figure 3 4 Attaching the Adhesive Feet 3 6 Figure 3 5 Inserting an SFP Transcei...

Page 13: ...xx...

Page 14: ...vering reliability and consistent performance for your network traffic They bring order to poorly performing networks by segregating them into separate broadcast domains with IEEE 802 1Q compliant VLA...

Page 15: ...connecting Ethernet cable Any 802 3af compliant device attached to a port can directly draw power from the switch over the Ethernet cable without requiring its own separate power source This capabilit...

Page 16: ...tion so you can use straight through cables for all network connections to PCs or servers or to other switches or hubs See 10 100BASE TX Pin Assignments on page B 2 Each of these ports support auto ne...

Page 17: ...nking indicates activity On Blinking Amber The port has a valid 10 Mbps link Blinking indicates activity Off There is no valid link on the port Gigabit Combination Ports Upper LED On Blinking Green Th...

Page 18: ...3 System Status LED Table 1 2 System Status LED LED Condition Status System On Green Internal power is operating normally On Amber Internal power supply has failed Off Power off or failure 25 27 26 2...

Page 19: ...tion mode half or full duplex if this feature is supported by the attached device otherwise the port can be configured manually Independent RJ 45 10 100BASE T ports with auto MDI MDI X pinout selectio...

Page 20: ...nt bridging Switching table with a total of 8K MAC address entries Provides store and forward switching Supports wire speed filtering and forwarding Supports flow control using back pressure for half...

Page 21: ...ice experiencing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize through...

Page 22: ...r to be supplied over the connecting cable Each of the 24 ports on the switch can provide power to a connected device In the figure below the switch is supplying power to three PoE devices It is also...

Page 23: ...panel or a Gigabit Ethernet port on a plug in SFP transceiver In the figure below the switch is operating as a collapsed backbone for a small LAN It is providing dedicated 100 Mbps full duplex connec...

Page 24: ...w the 10 100BASE TX ports on the switch are providing 100 Mbps connectivity through layer 2 switches In addition the switch is also connecting several servers at 1000 Mbps Figure 2 3 Network Aggregati...

Page 25: ...building a 1000BASE LX SFP transciever can be used to connect to other buildings in a campus setting and a 1000BASE ZX SFP transceiver can be used for a long haul connection to a remote site The figu...

Page 26: ...s should be used for larger networks and all the VLANs assigned to the inter switch links The switch also supports multiple spanning trees which allow VLAN groups to maintain a more stable path betwee...

Page 27: ...s it is actually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 As a general rule the length of fiber optic c...

Page 28: ...NETWORK PLANNING 2 8...

Page 29: ...ately two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted pair cable is always ro...

Page 30: ...shielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Category 5 or better for 1000BASE T Protec...

Page 31: ...foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power Cord RS 232 console cable This Installation Guide Management Guide CD Optional Ra...

Page 32: ...within a rack assembly may be higher than the ambient room temperature check that the rack environment temperature is within the specified operating temperature range See page C 2 Mechanical Loading D...

Page 33: ...ts to the device using the screws provided in the Bracket Mounting Kit Figure 3 2 Attaching the Brackets 2 Mount the device in the rack using four rack mounting screws not provided Figure 3 3 Installi...

Page 34: ...irst switch Figure 3 4 Attaching the Adhesive Feet 2 Set the device on a flat surface near an AC power source making sure there are at least two inches of space on all sides for proper air flow 3 If i...

Page 35: ...sceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP transceivers are keyed so they can only be installed in one orientation...

Page 36: ...Socket 2 Plug the other end of the cable into a grounded 3 pin socket Note For International use you may need to change the AC line cord You must use a line cord set that has been approved for the soc...

Page 37: ...ect to the serial port are described in the following figure and table Figure 3 7 Serial Port DB 9 DTE Pin Out Wiring Map for Serial Cable The serial port s configuration requirements are as follows D...

Page 38: ...INSTALLING THE SWITCH 3 10...

Page 39: ...onnected to devices using optional SFP tranceivers If 802 3af compliant PoE devices are connected to the switch s 10 100 Mbps ports the switch automatically supplies the required power Twisted Pair De...

Page 40: ...using the two signal wire pairs in UTP or STP cable RJ 45 pins 1 2 3 and 6 The switch can provide up to 15 4 W of power continuously on each 10 100 Mbps port However taking into account some power lo...

Page 41: ...45 port This will damage the switch Use only twisted pair cables with RJ 45 connectors that conform to FCC standards Connecting to PCs Servers Hubs and Switches 1 Attach one end of a twisted pair cabl...

Page 42: ...rmance for the segment attached to the hub Network Wiring Connections Today the punch down block is an integral part of many of the newer equipment racks It is actually part of the patch panel Instruc...

Page 43: ...ic cabling with an LC connector at both ends Each single mode fiber port requires 9 125 micron single mode fiber optic cable with an LC connector at both ends Warning This switch uses lasers to transm...

Page 44: ...Glasfasertransceiver mu auch ein berpr ftes Ger t der Laser Klasse 1 sein 1 Remove and keep the LC port s rubber cover When not connected to a fiber cable the rubber cover should be replaced to prote...

Page 45: ...be sure that the connection is valid The 1000BASE SX 1000BASE LX and 1000BASE ZX fiber optic ports operate at 1 Gbps full duplex with auto negotiation of flow control The maximum length for fiber opt...

Page 46: ...e Requirements All Category 5 UTP cables that are used for 100BASE TX connections should also work for 1000BASE T providing that all four wire pairs are connected However it is recommended that for al...

Page 47: ...ber Size Fiber Bandwidth Maximum Cable Length Connector 62 5 125 micron multimode fiber 160 MHz km 2 220 m 7 722 ft LC 200 MHz km 2 275 m 7 902 ft LC 50 125 micron multimode fiber 400 MHz km 2 500 m 7...

Page 48: ...5 Maximum Fast Ethernet Cable Length Type Cable Type Max Cable Length Connector 100BASE TX Category 5 or better 100 ohm UTP or STP 100 m 328 ft RJ 45 Table 4 6 Maximum Ethernet Cable Length Type Cabl...

Page 49: ...ly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it is...

Page 50: ...MAKING NETWORK CONNECTIONS 4 12...

Page 51: ...ycle the switch to try and clear the condition If the condition does not clear contact your dealer for assistance Link LED is Off Verify that the switch and attached device are powered on Be sure the...

Page 52: ...here you are sure that all the other components are functioning properly In Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet a Web b...

Page 53: ...Also an RJ 45 connector must be attached to both ends of the cable Caution Each wire pair must be attached to the RJ 45 connectors in a specific orientation Caution DO NOT plug a phone jack connector...

Page 54: ...le pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable When using any RJ 45 port on this switch you can use either straight throug...

Page 55: ...port on this switch you can use either straight through or crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to support Gigabit Ether...

Page 56: ...nabled for any RJ 45 port on this switch you can use either straight through or crossover cable to connect to any device type You must connect all four wire pairs as shown in the following diagram to...

Page 57: ...s for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters...

Page 58: ...devices Adjusting Existing Category 5 Cabling to Run 1000BASE T If your existing Category 5 installation does not meet one of the test parameters for 1000BASE T there are basically three measures that...

Page 59: ...uto MDI X 10BASE T RJ 45 100 ohm UTP cable Category 3 or better 100BASE TX RJ 45 100 ohm UTP cable Category 5 or better Ports 25 28 RJ 45 connector auto MDI X 1000BASE T RJ 45 100 ohm UTP cable Catego...

Page 60: ...F Humidity Operating 10 to 90 non condensing Power Supply Internal auto ranging transformer 100 to 240 V 50 60 Hz 3 A Power Consumption 225 Watts maximum Maximum Current 0 25 A 115 VAC 0 12 A 230 VAC...

Page 61: ...or XModem out of band Standards IEEE 802 3 Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3z and 802 3ab Gigabit Ethernet IEEE 802 1D Bridging IEEE 802 3x full duplex flow control IEEE 802 1Q Virtual LAN...

Page 62: ...SPECIFICATIONS C 4 Safety UL CUL UL 60950 1 CSA 22 2 NO60950 1 TUV GS EN60950 1 CB IEC60950 1...

Page 63: ...000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 125 micron core fiber cable 1000BASE T IEEE 802 3ab specification for Gigabit Ethernet over 100 ohm Categor...

Page 64: ...ct is the communication method employed by Ethernet Fast Ethernet or Gigabit Ethernet End Station A workstation server or other device that does not forward traffic Ethernet A network communication sy...

Page 65: ...sion detection CSMA CD access method and physical layer specifications IEEE 802 3ab Defines CSMA CD access method and physical layer specifications for 1000BASE T Gigabit Ethernet IEEE 802 3ae Defines...

Page 66: ...tween network nodes Modal Bandwidth Bandwidth for multimode fiber is referred to as modal bandwidth because it varies with the modal field or core diameter of the fiber Modal bandwidth is specified in...

Page 67: ...ary transport protocol and IP as the network layer protocol UTP Unshielded twisted pair cable Virtual LAN VLAN A Virtual LAN is a collection of network nodes that share the same collision domain regar...

Page 68: ...Glossary 6...

Page 69: ...ances EMC C 3 safety C 4 connectivity rules 10 Mbps 4 10 console port pin assignments 3 9 contents of package 3 3 cooling problems A 2 cord sets international 3 8 D desktop mounting 3 6 device connect...

Page 70: ...kage contents 3 3 pin assignments B 1 console port 3 9 DB 9 3 9 port saturation 1 3 ports connecting to 4 1 power connecting to 3 8 R rack mounting 3 4 rear panel receptacles 1 6 RJ 45 port 1 3 connec...

Page 71: ...INDEX Index 3 W Web based management 1 3...

Page 72: ...7200 info edgewaternetworks com Copyright 2010 Edgewater Networks Inc All rights reserved Converged Networking Simplified Please visit our website at www edgewaternetworks com or contact the Edgewater...