3-28
BATS
0018257_REV_A
COM#2 “USBL Transceiver”
The COM#2 port is used typically for a compass input. No data is transmitted from this port. The hardware
is setup for bi-directional communications but the Transceiver does not utilize its transmit capabilities.
The Transceiver’s COM#2 interface is designed to act as a Data Terminal Equipment (DTE) (E.g. Processor
Module or PC), If interfacing to a module that has the same protocol, a null modem is required between
the two devices.
The COM#2 port does not have hardware or software flow control capability. The hardware handshake
lines (RTS & DTR) are disabled and do not use the XOFF & XON protocol. If an overrun in data occurs the
data is lost and only the most recent is accepted. (In the case of a gyro or compass input you would not
want the old data but rather accept only the most recent.
Figure 3-19: BATS Cable COM#2 to Compass Data Diagram
3.4.9
BATS - COM#3 Pitch/Roll NMEA Input
(Cable Wiring; 9-PIN `D' CONNECTOR)
The BATS Transceiver COM #3 I/O port is wired the same as a PC
("DTE", Data Terminal Equipment). It is used for the input of NMEA Pitch and Roll sensors. See below for
wiring. If an EdgeTech MRU is interfaced to COM#3 the wiring has been crossed-over in the MRU so that
a null modem is not required. If the BATS is configured with the Micro-Modem option, COM #3 is used for
the Modem Communications only and COM#3 is no longer available to the BATS.
COM#3 “USBL Transceiver”
The COM#3 port is used typically for a motion sensor input. No data is transmitted from this port. The
hard-ware is setup for bi-directional communications but the Transceiver does not utilize its transmit
capabilities. The Transceiver’s COM#2 interface is designed to act as a Data Terminal Equipment (DTE)
(E.g. Processor Module or PC). If interfacing to a module that has the same protocol, a null modem is
required between the two devices.
The COM#2 port does not have hardware or software flow control capability. The hardware handshake
lines (RTS & DTR) are disabled and do not use the XOFF & XON protocol. If an overrun in data occurs the
Summary of Contents for USBL BROADBAND ACOUSTIC TRACKING SYSTEM
Page 20: ......
Page 26: ......
Page 28: ...SECTION 2 SPECIFICATIONS 2 2 BATS 0018257_REV_A Figure 2 1 BATS USBL Portable System ...
Page 29: ...2 3 Figure 2 2 Portable BATS Transceiver Figure 2 3 Portable BATS Transceiver Side Panel ...
Page 44: ...SECTION 2 SPECIFICATIONS 2 18 Figure 2 11 BATS Portable System Mechanical Outline 0020020 ...
Page 45: ...2 19 Figure 2 12 BATS Desktop System Mechanical Outline 0020022 ...
Page 46: ...SECTION 2 SPECIFICATIONS 2 20 Figure 2 13 BATS Rackmount System Mechanical Outline 0020017 ...
Page 52: ...3 6 Figure 3 3 Hydrophone Outline Drawing 0019592 ...
Page 53: ...3 7 Figure 3 4 Hydrophone MTG Arrangement Page 1 of 2 0020018 ...
Page 54: ...3 8 Figure 3 5 Pipe Angle Bracket Arrangement Page 2 of 2 0020018 ...
Page 55: ...3 9 Figure 3 6 Angle Bracket Drawing 007327 ...
Page 56: ...3 10 Figure 3 7 15m 50ft Deck Cable for Desktop 002936 ...
Page 57: ...3 11 Figure 3 8 30m 100ft Deck Cable for Desktop 0002935 ...
Page 58: ...3 12 Figure 3 9 Deck Cable for Portable 0003458 ...
Page 60: ...3 14 Figure 3 10 Suggested Mounting Arrangement in Machined Shaft Flange OTS 0010007 ...
Page 61: ...3 15 Figure 3 11 Suggested Hydrophone Shaft Machining Through Hull 0020019 ...
Page 62: ...3 16 BATS 0018257_REV_A Figure 3 12 Gate Valve Type Installation ...
Page 65: ...3 19 Figure 3 14 Hydrophone Mounting Diagram ...
Page 78: ...3 32 BATS 0018257_REV_A Figure 3 23 Sync Interface Connector Data Diagram on Desktop Unit ...
Page 79: ...3 33 Figure 3 24 Sync Interface Connector Desktop Console 0002566 ...
Page 80: ...3 34 Figure 3 25 Analog Interface Connector Data Diagram Desktop Console ...
Page 81: ...3 35 Figure 3 26 Analog Interface Connector Desktop Console 0002984 ...
Page 82: ...3 36 Figure 3 27 Ethernet Cable 1PPS 0002474 ...
Page 83: ...3 37 Figure 3 28 BATS Portable AC Cord 0002868 ...
Page 84: ...3 38 Figure 3 29 BATS Portable COMMS Cable 0014672 ...
Page 85: ...3 39 Figure 3 30 Portable BATS Synchronization Connector ...
Page 86: ...3 40 Figure 3 31 BATS Portable Sync Cable 0002567 ...
Page 87: ...3 41 Figure 3 32 Portable BATS Analog Input Connector Data Diagram ...
Page 88: ...3 42 Figure 3 33 BATS Portable Analog Connector Assembly Drawing 0002441 ...
Page 90: ......
Page 95: ...5 5 Figure 5 3 BATS Block Diagram 1 ...
Page 96: ...5 6 Figure 5 4 BATS Block Diagram 2 ...
Page 97: ...5 7 Figure 5 5 Portable BATS Block Diagram 1 ...
Page 98: ...5 8 Figure 5 6 Portable BATS Block Diagram 2 ...