2-15
ORE M-FSK SPREAD SPECTRUM WAVEFORMS
ORE-20
16.025 – 12.019
16.30
Directional (Typ)
Table 2-18: ORE M-FSK Spread Spectrum Waveforms
2.6.3
Hydrophone Codes
Hydrophone codes are the pulses sent out of the Hydrophone to interrogate the transponder.
CONTINUOUS WAVE (CW) INTERROGATE FREQUENCY CHANNEL CODES
CODE
FREQUENCY (kHz)
PULSE WIDTH (ms)
1
16.0
6
2
17.0
6
3
18.0
6
4
19.0
6
5
20.5
6
6
21.5
6
7
22.5
6
Table 2-19: CW Interrogate Frequency Channel Codes
Power Supply Specifications
POWER REQUIREMENTS
Voltage:
115-230 AC (auto switching)
Frequency:
50-60 Hz
Power:
60 Watts
Table 2-20: Desktop and Portable System Power Requirements
POWER REQUIREMENTS
Voltage:
115-230 AC (auto switching)
Frequency:
50-60 Hz
Power:
325 Watts
Table 2-21: Rackmount System Power Requirements
Temperature
Operating Temperatures for each system are detailed below.
Summary of Contents for USBL BROADBAND ACOUSTIC TRACKING SYSTEM
Page 20: ......
Page 26: ......
Page 28: ...SECTION 2 SPECIFICATIONS 2 2 BATS 0018257_REV_A Figure 2 1 BATS USBL Portable System ...
Page 29: ...2 3 Figure 2 2 Portable BATS Transceiver Figure 2 3 Portable BATS Transceiver Side Panel ...
Page 44: ...SECTION 2 SPECIFICATIONS 2 18 Figure 2 11 BATS Portable System Mechanical Outline 0020020 ...
Page 45: ...2 19 Figure 2 12 BATS Desktop System Mechanical Outline 0020022 ...
Page 46: ...SECTION 2 SPECIFICATIONS 2 20 Figure 2 13 BATS Rackmount System Mechanical Outline 0020017 ...
Page 52: ...3 6 Figure 3 3 Hydrophone Outline Drawing 0019592 ...
Page 53: ...3 7 Figure 3 4 Hydrophone MTG Arrangement Page 1 of 2 0020018 ...
Page 54: ...3 8 Figure 3 5 Pipe Angle Bracket Arrangement Page 2 of 2 0020018 ...
Page 55: ...3 9 Figure 3 6 Angle Bracket Drawing 007327 ...
Page 56: ...3 10 Figure 3 7 15m 50ft Deck Cable for Desktop 002936 ...
Page 57: ...3 11 Figure 3 8 30m 100ft Deck Cable for Desktop 0002935 ...
Page 58: ...3 12 Figure 3 9 Deck Cable for Portable 0003458 ...
Page 60: ...3 14 Figure 3 10 Suggested Mounting Arrangement in Machined Shaft Flange OTS 0010007 ...
Page 61: ...3 15 Figure 3 11 Suggested Hydrophone Shaft Machining Through Hull 0020019 ...
Page 62: ...3 16 BATS 0018257_REV_A Figure 3 12 Gate Valve Type Installation ...
Page 65: ...3 19 Figure 3 14 Hydrophone Mounting Diagram ...
Page 78: ...3 32 BATS 0018257_REV_A Figure 3 23 Sync Interface Connector Data Diagram on Desktop Unit ...
Page 79: ...3 33 Figure 3 24 Sync Interface Connector Desktop Console 0002566 ...
Page 80: ...3 34 Figure 3 25 Analog Interface Connector Data Diagram Desktop Console ...
Page 81: ...3 35 Figure 3 26 Analog Interface Connector Desktop Console 0002984 ...
Page 82: ...3 36 Figure 3 27 Ethernet Cable 1PPS 0002474 ...
Page 83: ...3 37 Figure 3 28 BATS Portable AC Cord 0002868 ...
Page 84: ...3 38 Figure 3 29 BATS Portable COMMS Cable 0014672 ...
Page 85: ...3 39 Figure 3 30 Portable BATS Synchronization Connector ...
Page 86: ...3 40 Figure 3 31 BATS Portable Sync Cable 0002567 ...
Page 87: ...3 41 Figure 3 32 Portable BATS Analog Input Connector Data Diagram ...
Page 88: ...3 42 Figure 3 33 BATS Portable Analog Connector Assembly Drawing 0002441 ...
Page 90: ......
Page 95: ...5 5 Figure 5 3 BATS Block Diagram 1 ...
Page 96: ...5 6 Figure 5 4 BATS Block Diagram 2 ...
Page 97: ...5 7 Figure 5 5 Portable BATS Block Diagram 1 ...
Page 98: ...5 8 Figure 5 6 Portable BATS Block Diagram 2 ...