5-64
6205s2 BATHYMETRIC AND SIDE SCAN SONAR
0025262_REV_A
5.0
INSTALLATION
This section provides an overview of unpacking, inspecting, installing, and caring for the EdgeTech 6205s2
Swath Bathymetry and Dual Frequency Side Scan Sonar System.
5.1
Unpacking and Inspecting
The sonar head and Topside Interface units are shipped in heavy-duty, reusable transport cases with
appropriate packing material. All documentation, including manuals, is provided in electronic form on the
USB thumb drive.
Before unpacking the system’s components, inspect the shipping containers for damage. If any damage is
found, report it to the carrier and to EdgeTech immediately. If the shipping containers appear damage-
free, carefully unpack the components and inspect them.
Check the packing list and verify all the items on the list are included. If any damage is found after
unpacking the components, immediately report it to the carrier and to EdgeTech. If any items are missing,
contact
. Do not install or operate any equipment that appears damaged.
Although the items shipped may vary depending on the customer’s requirements, the standard
components for the 6205s2 Swath Bathymetry and Dual Frequency Side Scan Sonar system are listed in
5.2
Sonar Head Installation
Installing the 6205s2 system on the survey vessel is the customer’s responsibility, but it is important to
keep the following considerations in mind.
1.
The sonar head can be mounted on the side of a vessel or on the underside of the vessel, but it is
recommended to secure the 6205s2 to the boat's bow.
2.
If the customer wishes to mount the sonar off their vessel's side/underside, care must be taken
to ensure keel clearance.
5.2.1
Pole Mounting
The 6205s2 is designed to be pole mounted to a pole flange using the 3-bolt plate provided on the top of
the sonar head. Customers can manufacture their own, or EdgeTech offers a kit that offers a flange
adaptor plate and the necessary hardware to attach it to a customer-supplied pole. Further information
Summary of Contents for 6205S2
Page 32: ...2 32 Figure 2 2 6205s2 Sonar Head with Adaptor Flange ICD...
Page 33: ...2 33 Figure 2 3 6205s2 Side Scan Transducer...
Page 34: ...2 34 Figure 2 4 6205s2 Side Scan Transducer Details...
Page 35: ...2 35 Figure 2 5 6205s2 Deck Cable Wiring Diagram...
Page 36: ...2 36 Figure 2 6 6205s2 GNSS INS Deck Cable Wiring Diagram...
Page 37: ...2 37 2 6 2 6205s2 Topside Figure 2 7 6205s2 Rack Mounted Topside...
Page 38: ...2 38 Figure 2 8 6205s2 Rack Mount in Case...
Page 41: ...3 41 3 1 2 2 Sonar Processor Endcap and Pinout Drawings Figure 3 5 6205S2 Forward End Cap...
Page 42: ...3 42 6205s2 BATHYMETRIC AND SIDE SCAN SONAR 0025262_REV_A Figure 3 6 6205s2 Aft End Cap...
Page 46: ...3 46 Figure 3 11 6205s2 Acoustic Center Location X Y Z and Bolt Pattern...
Page 47: ...3 47 Figure 3 12 6205s2 with Adaptor Flange Acoustic Center Location X Y Z and Bolt Pattern...