on the survey vessel, such as pumps and winches. Also, do not use switching-type battery chargers or DC
to AC converters with square wave outputs.
4.2.2
Change to a Non-US Power Plug
An AC power cord is provided for connecting the deck unit to a standard U.S. 3-pronged outlet. For non-
U.S. power outlets, users can modify this cord by cutting off the 3-pronged plug and attaching the
appropriate plug.
AC POWER CORD WIRE COLOR
FUNCTION
Black
AC line
White
AC neutral
Green
Earth ground
Table 4-1: AC Power Wiring Wire Colors for Conversion
4.3
Topside Processor Placement
The Starmux IV Rack Mount Topside should be located and set up in a dry, sheltered area that is protected
from weather and water spray. The unit also requires an environment where the temperature is
consistently between 0°C and 40°C (32°F and 104°F). Furthermore, avoid areas of direct sunlight,
especially in tropical environments, as heat buildup could damage the equipment, and glare could hinder
the user's ability to see LCDs, digital displays, and status indicator lights. The processor's location should
also allow users to communicate directly with the deck crew that is handling the towfish. Secure the
topside processor in place, using tie-downs if necessary, near the required AC power source. Also, ensure
that there is ample room behind the rack for connecting the cables. Support the components inside the
rack using appropriate mounting brackets and secure the front panels using standard 19-inch rack front
panel mounting hardware.
4.4
Connecting the System Components
All the system components, including optional components, such as a printer or additional displays,
connect to the topside processor.
The Starmux IV Topside digital link and computer are connected by an ethernet cable, as shown in
NOTE
The ethernet cable must be plugged into the right side ethernet
port on the computer and any one of the data ports on the Starmux IV.