Important Safety Information

 

 

Improper handling can cause serious damage to the appliance and/or to the 
user.  
 
This portable air conditioner is not intended for use by children. Children should 
be supervised to ensure that they do not play with this product. 
 

 

Your portable air conditioner is supplied with a Leakage-Current 
Detection and Interruption (LCDI) safety plug. This device provides 
protection to reduce the risk of fire due to arcing faults in the power 
supply cord. Before using your portable air conditioner, follow the 
instructions below to ensure that the LCDI plug is working properly:  
 
1.  Plug the power cord to a grounded outlet. 
2.  Press the TEST button on the LCDI plug. This should trip the 
plug and cut the power to the air conditioner. If the plug does not 
trip and you are able to turn on the unit, please contact EdgeStar 
support. 
 

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS. 

 
Press the RESET button to start using your air conditioner.  
 
Do not use the TEST and RESET buttons as an ON/OFF switch. 

Electrical Safety 

 

This unit is designed for indoor use only. 

 

Do not use the unit in extremely humid or wet environments. 

 

Do not wet the housing or control panel. 

 

Do not pull the unit by the cord. 

 

Always turn the unit off and unplug it from the socket when cleaning. 

 

Unplug the unit if it is not going to be used for a long period of time.  

 

Do not operate the unit with a damaged plug or a loose socket. 

 

Use only the correct power supply with appropriate amperage. 

 

If the power cord is damaged, it must be replaced by the manufacturer, 
a service agent, or qualified technician.  

 

Do not remove any part of the casing unless instructed by an 
authorized technician. 
 

General Safety 

 

This portable air conditioner is not intended to be used by children. 

 

Do not allow children to play with the controls or drop any objects into 
the air outlets or vents.  

 

Do not place objects or let any person sit on top of the unit.  

 

Only use in the upright position on a flat, level surface and provide at 
least 20 inches of clearance from any walls or objects.  

 

Route the power cord carefully to avoid a tripping hazard.  

 

This unit is intended for domestic use only. Do not use the portable air 
conditioner for industrial or commercial use.  Any other use may 
invalidate the warranty. 

 

RESET

TEST

Summary of Contents for AP12000HS-1

Page 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com AP12000HS 1...

Page 2: ...y This unit is designed for indoor use only Do not use the unit in extremely humid or wet environments Do not wet the housing or control panel Do not pull the unit by the cord Always turn the unit off...

Page 3: ...ECTOR TO THE GRATED ADAPTER 8 NOTES ABOUT THE EXHAUST HOSE 9 CONTROL PANEL OVERVIEW 10 OPERATING THE CONTROL PANEL 11 POWER 11 AUTO RESTART 11 COOLING MODE 11 DEHUMIDIFYING MODE 11 HEAT MODE 11 FAN ON...

Page 4: ...the ratings label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for...

Page 5: ...ts Identification Back View Front View Control Panel Front Air Vent Handle Caster Pre filter Air Intake Exhaust Outlet Power Cord Drain Valve CAUTION Make sure the rubber drain plug is firmly installe...

Page 6: ...eded It is necessary to clean the pre filter periodically Follow the steps below to install the carbon filter 1 Pull the handle on the pre filter straight up CAUTION Never operate the air conditioner...

Page 7: ...e power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as show...

Page 8: ...ter 1 Insert the round grated adapter through the back grooved side of the window kit plate with hole 2 Secure the grated adapter by fastening the screws from flat side of the window kit plate to the...

Page 9: ...ndow sill Then slide the window kit plate to fit the width of the window You can use screws to secure the window kit plate from sliding 4 Lower the window to secure the window kit in place You may nee...

Page 10: ...hose A B 5 Attach the connectors to the hose A Extend the ends of the exhaust hose B Thread the duct connector on by turning it clockwise until it stops 6 Roll the unit towards the window kit Leave a...

Page 11: ...ortable air conditioner and start using it Connecting the duct connector to the unit Connecting the duct connector to the grated adapter 7 Align the slots on the duct connector to the tabs and snap in...

Page 12: ...ditional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommended Draining the Unit Wh...

Page 13: ...mer button is enabled Indicator Function Water Light The water light will turn on if the unit has filled the internal water reservoir Timer Light The timer light indicates you have set the timer Use t...

Page 14: ...adjustable between 61 F 89 F in one degree increments in cooling mode During the Dehumidifying mode the unit will condense water out of the air and exhaust it through the exhaust hose The ambient temp...

Page 15: ...r the selected time passes the unit will automatically turn on How to set the unit to automatically turn off 1 Press the Timer button while the unit is powered on The Timer indicator LED will light up...

Page 16: ...e control will not be used for one month or longer Do not attempt to recharge batteries not designed to be recharged All batteries should be replaced at the same time Do not mix old and new batteries...

Page 17: ...urn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunligh...

Page 18: ...nse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly before reinstalli...

Page 19: ...orrectly A defective remote control Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fa...

Page 20: ...t to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The...

Page 21: ...tion of product Portable Air Conditioner Model AP12000HS 1 Voltage Frequency AC 115V 60Hz Input Power 1200W Cooling 1180W Heating Color Silver Dehumidifying capacity 81 Pints Day Coolant R 410A Timer...

Page 22: ...er installation unauthorized service mainte nance negligence unauthorized installation or modification or commercial use Labor service transportation and ship ping charges for the removal and replacem...

Page 23: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: