01/05
P/N 120413
13
User’s Manual
Installation
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Sensor Connections
Supply Voltage (Brown and Blue Wires), Pins 12 and 13
The Sensor requires a 10 to 30V dc power supply with 500 mA maximum current.
-----------------------------------------------------------
---------------------------------------------
Electrical Selection
The P4 inputs (Trigger, Product Change, Remote Teach, and Discrete) and outputs can be configured for either NPN (current
sourcing) or PNP (current sinking). This selection is made in the System Setup window on the
InputOutput
tab, shown below.
Once NPN or PNP is selected, all inputs/outputs are either NPN or PNP.
-------------------------------------------------------
System Setup Window InputOutput Tab
--------------------------------------------
The Sensor alone will operate properly with input voltage of 10-30V dc; however, if a light source is
powered by the Sensor, input voltage must be 24V dc ± 10%.
CAUTION