01/05
P/N 120413
133
User’s Manual
Run
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Run Log Tab
Run Screen Log Tab
Mode (default: None)
Pass:
Log only passed inspections based on Strategy.
Fail:
Log only failed inspections based on Strategy.
RT:
Log remotely-taught inspections based on Strategy.
RT Fail:
Log failed, remotely-taught inspections based on Strategy.
Any:
Log all inspections based on Strategy.
None:
Log not updated.
Strategy (default: First Ten)
First Ten:
Store the first 10 inspections that meet the mode criteria.
Last Ten:
Store the previous 10 inspections that meet the mode criteria.
First and Last Five:
Store the first 5 and last 5 inspections that meet the mode
criteria.
The
Log
tab on the Run screen enables the
user to select logging modes, specify how many
inspections to log and where, and specify what
to do with current results. Option descriptions
follow.