01/05
P/N 120413
131
User’s Manual
Run
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Run Select Tab
----------------------------------
Run Screen Select Tab
------------------------------------------------------
Product Select Line
-
The
Hardware Input
option signals the Sensor to run the option currently
selected by the Product Change and Product Select line. This option
allows the Product Change and Product Select input to change the
inspection. When the input to the Product Change pin becomes active, the
Sensor samples the Product Select pin and determines which inspection
to load from the Sensor memory.
-
The
Software Override
option signals the Sensor that the inspection to
run will be manually selected. With this option selected, the inspection
displayed next to the
Override
button is the inspection that runs.
The Product Change and Product Select Timing Diagram on the next page
shows the pin combinations and the resulting inspections.
The Product Change and Product Select line is used to swap between inspections. Select any of the (up to 12) stored
inspections to be the next inspection to run. A time delay, typically less than 1 second, is required to change the
inspections.
The
Select
tab on the Run screen enables the user to
specify Product Select lines and Image Hold and Trigger
Delay times. Option descriptions follow.