– 1 –
Quick Start Guide
Mount the Switch
1.
Attach the brackets to the switch.
2.
Use the screws and cage nuts supplied with the rack to secure
the switch in the rack.
Ground the Switch
1.
Ensure the rack on which the switch is to be mounted is properly
grounded and in compliance with ETSI ETS 300 253. Verify that
there is a good electrical connection to the grounding point on
the rack (no paint or isolating surface treatment)
2.
Attach a lug (not provided) to a #18 AWG minimum grounding
wire (not provided), and connect it to the grounding point on the
switch rear panel. Connect the other end of the wire to rack
ground.
Connect Power
a. Connecting AC Power
1.
Install one or two universal AC PSUs in the switch.
2.
Connect an external AC power source to the PSUs.
b. (Optional) Connecting DC Power
1.
Install one or two DC PSUs in the switch.
2.
Connect the DC power supply wires to the supplied connector as
follows:
■
A
–
Blue Wire: DC Return
■
B
–
Brown Wire:
-36 – -72 VDC
■
C
–
Yellow Wire - Chassis Ground
3.
Insert the DC supply connector into the DC PSU power input
socket.
Note:
The switch can also be installed on a desktop or shelf
using the included adhesive rubber foot pads.
Caution:
The earth connection must not be removed unless
all supply connections have been disconnected.
Attention:
Le raccordement à la terre ne doit pas être retiré
sauf si toutes les connexions d’alimentation ont été
débranchées.
1
2
1
2
1
2
Caution:
The device must be installed in a restricted-access
location. It should have a separate protective earthing terminal
on the chassis that must be permanently connected to earth to
adequately ground the chassis and protect the operator from
electrical hazards.
Attention:
L’appareil doit être installé dans un emplacement
à accès restreint. Il doit comporter une borne de terre de
protection distincte sur le châssis, qui doit être connectée en
permanence à la terre pour assurer une mise à la terre
adéquate du châssis et protéger l’opérateur des risques
électriques.
Note:
For international use, you may need to change the AC
line cord. You must use line cord sets that have been approved
for the socket type in your country.
3
1
2
1
1
2
A
B
C
1
3
E072020-CS-R01
150200002210H
www.edge-core.com
16-Port L2+/L3 Lite 10G Switch with Two 40G Uplinks
ECS5520-18X | ECS5520-18T
1.
ECS5520-18X or ECS5520-18T (with 1 AC PSU)
2.
Rack Mounting Kit—2 brackets and 8 screws
3.
Four adhesive rubber feet
4.
Power cord
5.
Console cable—RJ-45 to DB-9
6.
Documentation—
Quick Start Guide
(this document) and
Safety and Regulatory Information
2
5
1
4
3
6