–  1  –

Quick Start Guide

Mount the Switch

1.

Attach the brackets to the switch.

2.

Use the screws and cage nuts supplied with the rack to secure 
the switch in the rack. 

Ground the Switch

1.

Ensure the rack on which the switch is to be mounted is properly 
grounded and in compliance with ETSI ETS 300 253. Verify that 
there is a good electrical connection to the grounding point on 
the rack (no paint or isolating surface treatment)

2.

Attach a lug (not provided) to a #18 AWG minimum grounding 
wire (not provided), and connect it to the grounding point on the 
switch rear panel. Connect the other end of the wire to rack 
ground.

Connect Power

a. Connecting AC Power

1.

Install one or two universal AC PSUs in the switch.

2.

Connect an external AC power source to the PSUs.

b. (Optional) Connecting DC Power

1.

Install one or two DC PSUs in the switch.

2.

Connect the DC power supply wires to the supplied connector as 
follows:

– 

Blue Wire: DC Return

– 

Brown Wire: 

-36 – -72 VDC

C

– 

Yellow Wire - Chassis Ground

3.

Insert the DC supply connector into the DC PSU power input 
socket.

Note:

 The switch can also be installed on a desktop or shelf 

using the included adhesive rubber foot pads.

Caution:

 The earth connection must not be removed unless 

all supply connections have been disconnected.

Attention:

 Le raccordement à la terre ne doit pas être retiré 

sauf si toutes les connexions d’alimentation ont été 
débranchées.

1

2

1

2

1

2

Caution:

 The device must be installed in a restricted-access 

location. It should have a separate protective earthing terminal 
on the chassis that must be permanently connected to earth to 
adequately ground the chassis and protect the operator from 
electrical hazards.

Attention:

 L’appareil doit être installé dans un emplacement 

à accès restreint. Il doit comporter une borne de terre de 
protection distincte sur le châssis, qui doit être connectée en 
permanence à la terre pour assurer une mise à la terre 
adéquate du châssis et protéger l’opérateur des risques 
électriques.

Note:

 For international use, you may need to change the AC 

line cord. You must use line cord sets that have been approved 
for the socket type in your country.

3

1

2

1

1

2

A

B

C

1

3

E072020-CS-R01
150200002210H

www.edge-core.com

16-Port L2+/L3 Lite 10G Switch with Two 40G Uplinks

ECS5520-18X | ECS5520-18T

1.

ECS5520-18X or ECS5520-18T (with 1 AC PSU)

2.

Rack Mounting Kit—2 brackets and 8 screws 

3.

Four adhesive rubber feet

4.

Power cord

5.

Console cable—RJ-45 to DB-9

6.

Documentation—

Quick Start Guide

 (this document) and 

Safety and Regulatory Information

2

5

1

4

3

6

Package Contents

*150200002210H_R01*