1. Unpack the Switch and Check Contents

ECS4100-12T

ECS4100-12PH

ECS4100-28TC

ECS4100-26TX

ECS4100-26TX-ME

ECS4100-28T

ECS4100-28P

ECS4100-52T

ECS4100-52P

Rack Mounting Kit—two brackets and eight screws 

Four adhesive foot pads

Power Cord—either Japan, US, Continental Europe 
or UK

Console Cable—RJ-45 to DB-9

Documentation—

Quick Start Guide

 (this document) 

and 

Safety and Regulatory Information

Note:

 The ECS4100 series switches are for indoor use only.

Note:

 

 

For safety and regulatory information, refer to the 

Safety and Regulatory Information

 document included with 

the switch.

Note:

 

 

Other documentation, including the 

Web 

Management Guide,

 and 

CLI Reference Guide

, can be 

obtained from 

www.edge-core.com

.

2. Mount the Switch

Attach the brackets to the switch.

Use the screws and cage nuts supplied with the rack to 
secure the switch in the rack.

Caution:

 Installing the switch in a rack requires two 

people. One person should position the switch in the rack, 
while the other secures it using the rack screws.

Note:

 The switch can also be installed on a desktop or shelf 

using the included adhesive rubber foot pads.

3. Ground the Switch

Ensure the rack on which the switch is to be mounted is 
properly grounded and in compliance with ETSI ETS 300 253. 
Verify that there is a good electrical connection to the 
grounding point on the rack (no paint or isolating surface 
treatment).

Attach a lug (not provided) to a #18 AWG minimum 
grounding wire (not provided), and connect it to the 
grounding point on the switch using a 3.5 mm screw and 
washer. Then connect the other end of the wire to rack 
ground.

Caution:

 The earth connection must not be removed 

unless all supply connections have been disconnected.

Caution:

The device must be installed in a restricted-access 

location. It should have a separate protective earthing 
terminal on the chassis that must be permanently 
connected to earth to adequately ground the chassis and 
protect the operator from electrical hazards.

2

1

1

2

1

2

1

2

E042018-KS-R01
150200001807A

www.edge-core.com

 

ECS4100 Series Switch

Q ui c k   St a r t   G u i d e

Summary of Contents for ECS4100-26TX

Page 1: ...tion the switch in the rack while the other secures it using the rack screws Note The switch can also be installed on a desktop or shelf using the included adhesive rubber foot pads 3 Ground the Switc...

Page 2: ...LEDs should be on green 1 1 2 2 1 3 1 2 3 1 1 6 Perform Initial Configuration Connect a PC to the switch console port using the included console cable Configure the PC s serial port 115200 bps 8 char...

Page 3: ...95 Power Specification AC Input Power 12T 100 240 VAC 50 60 Hz 0 75 A 12PH 100 240 VAC 50 60 Hz 4A 26TX 100 240 VAC 50 60 Hz 1 A 28T 100 240 VAC 50 60 Hz 1 A 28TC 100 240 VAC 50 60 Hz 0 75 A 28P 100...

Page 4: ...ECS4100 12PH ECS4100 28TC ECS4100 26TX ECS4100 26TX ME ECS4100 28T ECS4100 28P ECS4100 52T ECS4100 52P RJ 45 DB 9 EC4100 Web CLI www edge core com 2 2 1 1 3 ETSI ETS 300 253 18 AWG 3 5mm 4 a 2 1 2 1...

Page 5: ...0 bps 8 8 CLI admin admin Web CLI 2 1 3 1 2 3 1 3 1 2 1 2 3 7 RJ 45 100 ohm Category 5 5e SFP SFP SFP SFP 1000BASE SX ET4201 SX 1000BASE LX ET4201 LX 1000BASE ZX ET4201 ZX 1000BASE LHX ET4201 LHX 10GB...

Page 6: ...CS4100 12PH AC 12T 100 240 50 60 Hz 0 75 A 12PH 100 240 50 60 Hz 4A 26TX 100 240 50 60 Hz 1 A 28T 100 240 50 60 Hz 1 A 28TC 100 240 50 60 Hz 0 75 A 28P 100 240 50 60 Hz 4 A 52T 100 240 50 60 Hz 1 A 52...

Page 7: ...CS4100 26TX ECS4100 26TX ME ECS4100 28T ECS4100 28P ECS4100 52T ECS4100 52P 2 8 4 RJ 45 DB 9 ECS4100 Safety and Regulatory Information Web CLI www edge core com 2 2 1 1 3 ETSI ETS 300 253 18 AWG 3 5 m...

Page 8: ...45 PC 115200 bps 8 1 8 admin admin CLI CLI 2 1 3 1 2 3 1 3 1 2 1 2 3 7 RJ 45 100 ohm Category 5 5e SFP SFP SFP SFP 1000BASE SX ET4201 SX 1000BASE LX ET4201 LX 1000BASE ZX ET4201 ZX 1000BASE LHX ET420...

Page 9: ...12PH AC 12T 100 240 VAC 50 60 Hz 0 75 A 12PH 100 240 VAC 50 60 Hz 4A 26TX 100 240 VAC 50 60 Hz 1 A 28T 100 240 VAC 50 60 Hz 1 A 28TC 100 240 VAC 50 60 Hz 0 75 A 28P 100 240 VAC 50 60 Hz 4 A 52T 100 2...

Reviews: