A.
The ignition harness is attached to the main harness with the connector, as shown at left below, and at the coil with the ring terminals on the
right below. The ground goes to the rear of the cylinder head. Connect the red and brown wires to the positive and negative terminals of the coil
as shown below.
IGNITION HARNESS
TO MAIN HARNESS
J6 IGNITION COIL
GROUND TO REAR
CYL HEAD
RED (COIL +)
BROWN (COIL -)
B.
The connector on left end (as drawn) of this 10-foot fuel pump wiring harness attaches to the Main System Harness. The two connectors on the
right connect to the positive (+) and negative (-) terminals on the fuel pump. A sleeve and tie-wrap are provided to fit over the positive terminal
once the connector is installed. This sleeve prevents the clamp from shorting the fuel pump terminals.
BLK
ORN
10'
B L K
O R N
BA
-
+
The fuel injector connectors are identical, but they are
placed in logical sequence. Refer to the diagram when
installing the harness connectors to the fuel injectors. In
addition to the Main System Harness, the Pro-Flo system
includes these shorter harnesses:
A. Ignition Coil to Main System Harness
B. Fuel pump to Main System Harness