Inspection Techniques
Magnetic Flux Leakage (MFL)
Internal Rotary Inspection System (IRIS)
Probe inputs
4 on 19-pin RFT/NFT/MFL connector
8 on 41-pin E
XTENDED
ET connector
Receiver gain
41 dB range, 23 – 64 dB
Connector type
19-pin RFT/NFT/MFL connector
41-pin E
XTENDED
ET connector
Number of UT channels
1, pulse-echo
Transducer frequency
5 MHz, 10 MHz, 15 MHz, or 20 MHz
Pulsing rate
Up to 30 kHz
Pulser voltage
75 – 200 V (25 V steps)
Pulse width
Automatically adjusted for transducer
frequency
Receiver gain
8 – 72 dB (in 1 dB steps)
Receiver DAC
Up to 20 dB/µs
RF Filters
4 user-selectable filters for 5 MHz,
10 MHz, 15 MHz, and 20 MHz
transducers
Digitizer
12 bits, 100 MHz
Gates
3; target pin, front wall, back wall
Summary of Contents for Ectane 2