3.5 Designated Use
• DCCF
-150 and-205 provide both central heating and
domestic hot water.
• DCBF-125 and DCBF
-165 central heating only.
•
Indoor installation.
•
Closet or alcove installation. Direct Vent Boiler does not
require air vents when installed in closet or room.
•
Direct vent boiler.
•
For use with natural gas or liquefied petroleum gases
(LP/propane).
3.6 The unit MUST NOT:
•
Directly heat potable water. Indirect heating is
acceptable.
•
Heat water with non-hydronic heating system
chemicals present (example, swimming pool water).
•
Toxic chemicals, such as those used for boiler
treatment, shall not be introduced into potable water
used for space heating.
•
Exceed 43 psig (2.96 bar) maximum system pressure,
or drop below minimum system pressure 7.25 psig
(.50 bar)
•
Exceed 176°F (80°C) system design temperature.
3.7 Operational Features
• DCBF-125
Modulates input to provide CH Turndown
5.7:1
• DCCF-150
Modulates input to provide CH Turndown
5.7:1, DHW Turndown 7:1
• -165
Modulates input to provide CH Turndown 5.5:1
• DCCF-205
Modulates input to provide CH Turndown
5.5:1, DHW turndown 7:1
•
Maximum output available for domestic hot water:
DCCF-150
- 136,000 btu/h (40 kW), capable of
providing 3.5 (U.S.) gpm (13.2 liters/min) with a
temperature rise of 70°F/39°C.
-205
- 180,000 btu/h (53 kW), capable of providing 5.0
(U.S.) gpm (18.9 liters/min) with temperature rise of
70°F/39°C.
•
Integral Low Water Pressure Cutoff.
•
Optional Outdoor Temperature Reset.
•
Heat exchanger over heat protection.
• Boiler operating at maximum operating temperature,
providing heat, pressure gauge should not indicate
more than 26.11 psi / 1.80 bar. If reading exceeds this
figure larger expansion tank is required.
3 - Introduction
3.1
Installation shall conform to requirements of authority
having jurisdiction or in absence of such requirements:
UNITED STATES
•
National Fuel Gas Code, ANSI Z223.1/NFPA 54
.
•
National Electrical Code, NFPA 70.
3.2
Where required by authority having jurisdiction,
installation shall conform to Standard for Controls and Safety
Devices for Automatically Fired Boilers, ANSI/ASME CSD-1.
Additional manual reset low water cutoff may be required.
3.3 Requirements for Commonwealth of
Massachusetts:
Boiler installation must conform to Commonwealth of
Massachusetts code 248 CMR which includes but is not limited
to:
Installation by licensed plumber or gas fitter.
3.4 Manufacturer recommends use of Carbon
Monoxide monitor may be requirement of local
jurisdiction.
3 - INTRODUCTION
240012879 REV A, [01/31/2020]
Summary of Contents for Dunkirk DCBF-125
Page 63: ...61 A 1 MODELS 125 Heat Only APPENDIX A WIRING DIAGRAMS 240012879 REV A 01 31 2020...
Page 64: ...62 APPENDIX A WIRING DIAGRAMS A 2 MODELS 165 Heat Only 240012879 REV A 01 31 2020...
Page 65: ...63 A 2 MODELS 150 Combi APPENDIX A WIRING DIAGRAMS 240012879 REV A 01 31 2020...
Page 66: ...64 A 4 MODELS 205 Combi APPENDIX A WIRING DIAGRAMS 240012879 REV A 01 31 2020...
Page 67: ...65 NOTES 240012879 REV A 01 31 2020...
Page 68: ...66 NOTES 240012879 REV A 01 31 2020...
Page 99: ...29 MODEL 150F Combi 150F FLOOR STANDING COMBI WIRING DIAGRAM PN 240012875 REV A 01 31 2020...
Page 101: ...31 205F FLOOR STANDING COMBI WIRING DIAGRAM MODEL 205F Combi PN 240012875 REV A 01 31 2020...
Page 106: ...36 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240012875 REV A 01 31 2020...
Page 114: ...44 NOTES PN 240012875 REV A 01 31 2020...