Summary of Contents for WS80

Page 1: ...Unpacking 3 3 Overview 5 4 Setup Guide 6 4 1 Install batteries in sensor package 6 4 2 Mount ultrasonic anemometer assembly 8 5 Wi Fi Configure with gateway 16 5 1 Pair with gateway or display console 16 5 2 Wi Fi Connection 16 6 View Online Data on WS View 17 7 Specification 18 8 Warranty Information 20 ...

Page 2: ...e Ultrasonic Sensor is solar powered and sends data to the console via a low power radio The data can be streamed by GW1000 Wi Fi Gateway sold separately or HP2551 console display sold separately and can be viewed on our WS View mobile application after the Wi Fi configuration done To ensure the best product performance please read this manual and retain it for future reference ...

Page 3: ...perature humidity sensor integrated optional heater for climate with snow ice conditions available 1 U Bolts set for mounting on a pole 2pcs set 1 Threaded nuts for U Bolts set M5 size 4pcs set 1 Mounting arm for ultrasonic anemometer 1 Mounting bracelet for ultrasonic anemometer 1 User manual this manual Table Package content If any component is missing from the package or broken please contact o...

Page 4: ...cell Note There s a built in heat plate in the 6 in 1 sensor package body if the lowest temperature at your place is below 3 C or 26 6 F and the weather is mostly snowy or rainy then you may need to activate the heater by supplying an external 5V 1A power to the sensor heating element for melting accumulated snow or ice which can influence wind measurement accuracy significantly Please contact us ...

Page 5: ...5 3 Overview Figure 1 Sensor package assembly components ...

Page 6: ... Sensor package assembly component list 4 Setup Guide 4 1 Install batteries in sensor package Open the battery compartment with a screwdriver and insert 2 AA batteries in the battery compartment and press Reset button the LED indicator on the back of the sensor package item 4 will turn on for 3 seconds and then flash once every 4 8 seconds indicating sensor data transmission If you did not pay att...

Page 7: ...et button Figure 2 Battery installation diagram Note Please make sure the battery is inserted correctly for its polarity as the system needs its initial power from this backup battery to start up the systembefore solar panel charges up the accumulator and supply system power afterwards when in high altitude area during wintertime sunshine time is short thus system needs to be powered from this bac...

Page 8: ...orbidden to be used with this anemometer when heater function is activated 4 2 Mount ultrasonic anemometer assembly 4 2 1 Before you mount Before installing your outdoor sensor in the permanent location we recommend operating the device for one week in a temporary location with easy access This will allow you to check out all of the functions ensure proper operation and familiarize you with the de...

Page 9: ...ccommodate a pole diameter of 1 25 2 inches pole not included 1 Install the base on a pole 1 25inch 2inch as Figure 3 Figure 3 Sensor package mounting diagram 5 1 2 Pass the connector cord through the arm tube as Figure 4 ...

Page 10: ...10 Figure 4 Sensor package mounting diagram 5 2 ...

Page 11: ...base as Figure 6 Be sure to line up the small hole in the arm with the holes in the base Insert the machine screw through the holes in the base and arm if you don t need to power up the heater you should keep the power cord terminal inside the mounting arm and this can make the installation looks neat and tidy You may take it out when needed ...

Page 12: ...12 ...

Page 13: ...sure the mounting pole is vertical or very close to it Use a level as needed 5 If optional extension cord is added connect the cord to the connector and insert the USB port into the AC adaptor as Figure 7 show Figure 7 Sensor package mounting diagram 5 5 ...

Page 14: ...row points due north To achieve proper alignment it is helpful to use a compass many cell phones have a compass application Once rotated in the correct orientation lightly tighten the bolts a little more use a wrench to prevent further rotation Note In Southern hemisphere it is not necessary to change the orientation to SOUTH as its solar panel is a rounded type and it is orientation free for its ...

Page 15: ...n but make sure strong wind and or rain cannot move the sensor package 4 2 3 Reset Button and Transmitter LED In the event the sensor package is not transmitting reset the sensor Using a bent open paperclip press and hold the RESET BUTTON item 12 to affect a reset the LED turns on while the RESET button is depressed and you can now let go The LED should then resume as normal flashing approximately...

Page 16: ...1 display console 1 Power on the gateway first with USB connection or HP2550 HP2551 display console with adaptor connection 2 Power on the Ultrasonic sensor 3 The RF status indicator of the gateway will light on steady and light off once when it receives the data from the optional sensor s once 4 If work normally you can forward to the Wi Fi connection operation 5 2 Wi Fi Connection For this part ...

Page 17: ...17 6 View Online Data on WS View When the Wi Fi configuration is done you can view the live data of your ultrasonic sensor on the WS View application only for the GW1000 gateway ...

Page 18: ...s 5m s the wind speed is detected by 1s when the maximum wind speed of the last 4s is 3m s and less than 5m s the wind speed is detected by 2s when the maximum wind speed of the last 4s is 3m s the wind speed is detected by 4s The wind speed reading will be a real time value The latest sampling data will be reporting to the receiver The wind gust reading will be the max wind speed in the past 28s ...

Page 19: ...0 1 0 1 Humidity 1 99 5 1 Light 0 300Klux 15 10Lux UVI 1 15 2 1 7 3 Power consumption Power Specification Anemometer sensor Solar panel built in 6 5V 4mA Anemometer sensor backup 2 x AA 1 5V Lithium battery not included Note The primary power source for the sensor is the solar panel When available solar power light over recent period is insufficient the batteries will be used ...

Page 20: ...riginal date of purchase is valid only on products purchased and only to the original purchaser of this product To receive warranty service the purchaser must contact us for problem determination and service procedures This limited warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustme...

Reviews: