EcoWater Waterworks WS 2000 Installating And Operation Manual Download Page 1

Summary of Contents for Waterworks WS 2000

Page 1: ...WS 2000 Installation Operation Maintenance Repair Parts IF YOU HAVE QUESTIONS WHEN INSTALLING OPERATING AND MAINTAINING YOUR CONDITIONER AND WHEN SETTING THE TIMER o CALL TOLL FREE 1 800 86 WATER Man...

Page 2: ...Y In addition to any warranty extended to you on the Water Works merchandise involved which warranty becomes effective the date the merchandise is installed should the workmanship of any Sears arrange...

Page 3: ...WARRANTY_ SAFETY GUIDES 2 SPECIFICATIONS DIMENSIONS 4 BEFORE STARTING INSTALLATION 5 TYPICAL INSTALLATION ILLUSTRATION 6 INSTALLATION STEPS 7 10 PROGRAMMING THE PREMIUM DEMAND TIMER 10 11 SANITIZING...

Page 4: ...NIMUM FLOW RATE gpm REGENERATION CYCLEFLOW RATES gpm FILL flow to brine tank BRINING 7 BRINE RINSEL flow to BACKWASH I drain FASTRINSE J 50 3 8 _9 14 _ INLET O_U_TL_ 3 7 8 I 18_1 4 _ 41 5 8 t 3 16 12...

Page 5: ...age 6 In and out fittings included with the softener are 1 nominal copper sweat tubes To maintain full valve flow 1 pipes to and from the softener fittings are recommended You should maintain the same...

Page 6: ...threaded plumbing buy 1 adaptors either sweat solder or compression to con nect to the 1 copper tubes 1 copper tube 2 2 Bypass Valve 4 INSTALLATION USING 3 VALVE BYPASS BRINE TANK NOT SHOWN J I I rJ...

Page 7: ...ubes figures 1A and 1B Be sure they snap into place Pull on the bypass valve and or copper tubes to make sure they are held securely in place FIGURE 1 _ clip 2 copper tubes install in softener valve o...

Page 8: ...AIN HOSE Take a length of 5 8 inside diameter garden hose 15 included and attach to the valve drain fitting Locate the other end of the hose at a suitable drain point floor drain sump laundry tub etc...

Page 9: ...bypass valve s in bypass position On a single valve slide the stem inward to BY PASS see page 8 On a 3 valve system close the inlet and outlet valves and open the bypass valve see page 6 C Fully open...

Page 10: ...ELECTRICAL POWER The softener works on 24 volt 60 Hz electric pow er The included transformer changes standard 120 volt AC house power to 24 volts Plug the trans former into a 120 volt outlet only Be...

Page 11: ...ows 2 When the present time shows press SETto ap ply If the present time is be I tween midnight and noon be sure AM shows SET WATER HARDNESS NUMBER NOTE If 25 factory default and HARDNESS do not show...

Page 12: ...above sanitizing regeneration is over your house COLD water supply is fully soft immediately However your water heater is filled with hard water and as hot water is used it will refill with soft water...

Page 13: ...minerals to eliminate these problems and others Sodium Information Water softeners using sodium chloride salt for regeneration add sodium to the water Persons on sodium restricted diets should consid...

Page 14: ...eaned This cleaning is called regeneration or re charge The Ultra demand timer automatically de termines when regenerations occur Regeneration is started at 2 00 a m factory setting by the soften er t...

Page 15: ...OUT IN OUT IN salt storage salt storage tank tank not shown brine valve brine valve resin tank resin bed fill water BRINING BRINE RINSE BACKWASH FAST RINSE brine valve hard water hard water hard water...

Page 16: ...f salt it is hard to tell if you have a salt bridge Salt is loose on top but the bridge is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bot...

Page 17: ...d only Do not over tighten and break the cap or hous ing Cap _ O ring Seal _ 0 Screen Support _ Screen _ _ _ _1 _ Nozzle Venturi _ _ Gasket _ _ tered directly over the small holes in the nozzle ventur...

Page 18: ...bottom portion of the dis play area These are CAPACITY remaining This is REMAINING CAPACt FLOW RATE GPM the percentage of water softening _ AT _oGALLO ST_O _ capacity remaining Immediately O W OA LVQ...

Page 19: ...h do not hold the TOUCH HOLD button and RECHARGE TONIGHT flashes in the time display area A regeneration will occur at the next preset re generation start time If you decide to cancel this re generati...

Page 20: ...ides the most economi cal operation You can set a maximum time in days between regenerations For example no more than 3 days will pass without a regeneration occurring if you set dY 3 in the display A...

Page 21: ...in standard clock time 12 00AM to 11 59PM If 24 hr is set time displays are in military time 0100 1 00AM to 0000 midnight To change from the 12 hr setting do steps 1 2 4 5 6 and 8 GALLONS OR LITERS M...

Page 22: ...ror code will return if the reason for the error code was not corrected service TIMER SOFTENER SERVICE CHECKOUT PROCEDURE If you are not getting soft water and an error code is not displayed use the p...

Page 23: ...al repeats display for each gallon of water passing through the meter If you don t get a reading in the display with faucet open pull the sensor from the valve outlet port Pass a small magnet back and...

Page 24: ...After observing fill press the TOUCH HOLD but ton to move the softener into brining A slow flow of water to the drain will begin Verify brine draw from the brine tank by shining a flashlight into the...

Page 25: ...distributor soft 3 distributor resin tank resin tank BRINING and BRINE RINSE CYCLES bypasshard water to valve outlet venturi BACKWASH CYCLE nozzle brine from salt stor age tank from Valve Inlet FAST...

Page 26: ...WaterWorks TM AUTOMATIC WATER CONDITIONER REPAIR PARTS SOFTENER ASSEMBLY 14 15 J Valve Assembly _ _ seepages28and29 9 10 12 11 J 3O 31 _ _ 36 35 2c 21 23 i i 27 29 26...

Page 27: ...n 53 Ibs 1 cuft Resin Tank 9 dia x 40 Bottom Cover Faceplate Cover also order following decal Decal Faceplate T_mer PWA Wire Harness Power Cord Transformer KEY I PART NO I NO 19 I 7192785 20 I 7163689...

Page 28: ...WaterWorks AUTOMATIC WATER CONDITIONER REPAIR PARTS 1 VALVE ASSEMBLY _ 2 46 __ 3 45 4 5 I_ 7 flow plug assembly__ _ assembled 25 10 9 15 16 22 2O 47 31 28 30 29 24 22 23 21 28...

Page 29: ...al Spring Clip 4 req 2 not shown Copper Tube 1 2 req O ring 1 1 8 x 1 3 8 4 req Turbine Support Turbine Sensor Housing O ring Retainer Nozzle Venturi Seal Nozzle Venturi O Valve Body O ring 1 4 x 3 8...

Page 30: ...WaterWorks AUTOMATIC WATER CONDITIONER NOTES 30...

Page 31: ...WaterWorks AUTOMATIC WATER CONDITIONER NOTES 31...

Page 32: ......