Eco 250
Getting Started
Electrical Requirements:
The system requires 208
–
220 volt, 3 phase, 30 amps, 4 wire system WYE Wired
and will run on 50 or 60 HZ.
This electrical connection should be a straight run back to the panel and the
breakers marked to distinguish the Eco 250 connections from any other installed
service.
You must supply both electrical connectors for your site
1. Wall to electrical panel
2. And System to wall (Your electrician will be able to assist you with these
requirements)
Physical Requirements: (45.3”*39.4”*41.4”):
The Eco 250 units come with casters that lock for easy positioning of the unit.
The unit can be placed outside provided that the unit is protected from the
elements. Rain, snow and ice can and will damage the electrical portions of the
unit.
A drain line, to remove condensate from the system is included. The condensate
can then go directly to the main drain as it contains no chemicals or sediments and
is gravity fed.
The drain must be below the output from the unit and must drain away from the
unit to insure fluid movement.
A heater switch for the water reservoir is provided for colder climates to keep the
water from freezing (see operator manual)