Please read these instructions completely before operating the 

ecosmart™ Fire.

These models are suitable for use both indoors and outdoors.
There are no requirements for side and/or overhead clearances as 

spacers are part of the design. 

The appliance cavity should include a layer of cement sheeting prior to 

inserting the appliance to limit heat transference. Missing heat insulation 

can cause overheating, which may result in damages to the material 

surrounding the appliance.

DO NOT PACK REQUIRED AIR SPACES (THE SPACE bETwEEN 

THE APPLIANCE AND THE SPACER) wITH INSULATION OR 

OTHER MATERIALS. THE AIR SPACES ARE NEEDED FOR PROPER 

VENTILATION OF THE bURNER.

WARNING: Ensure that your fire is positioned away from flammable 

materials and other sources of ignition at all times. Pay very close 

attention to positioning the fire away from items that may move as 

a result of wind and drafts. 

For example trees/branches/curtains/

paper and the like. 

Note: Stainless steel will rust or corrode over time if contamination 

or debris is not cleaned or removed immediately. when not in use, it 

is recommended that you protect your fireplace from water damage 

or corrosion with a protective cover and always use the burner Lid 

included with your model to safeguard the burner.

Fireplace inserts 

Clearances

Fireplace inserts 

installation

The zero clearance appliance inserts are designed for installation into 

a wall or cavity made from combustible or non-combustible materials. 

They are engineered specifically to accept EcoSmart Fire Burners. 

Appliances

 must be installed into a fixed secure position before being 

operated. They can be fitted from either the front side of the flange 

or from the back of the flange (screwed, riveted or glued with a high 

temperature resistant bonding product) onto the surrounding structural 

framework. 

The floor must be level and the 

appliance

 positioned on a flat surface. 

The appliance must be installed in a setting that is built to safely hold 

the weight of the model. In the case of insufficient capacity to hold the 

weight of the model, measures must be taken to reinforce the setting 

(for example installation of a plate for load distribution) so that the 

setting is suitable for installation.

notiCe: do not install direCtlY Beside or near 

WallPaPer, laMinate, Veneer or anY sUrFaCe tHat 

HAS NOT BEEN FIRE RATED (the heat will impact the material, 

and in some circumstances the glue used for its application). 

tHis inClUdes tHe detailinG/FinisHinG Materials Used 

on tHe deCoratiVe sUrFaCes aroUnd tHe installed 

aPPlianCe. reFer to tHe ProdUCt sPeCiFiCation oF tHe 

WallPaPer, laMinate, Veneer, GlUe or otHer BeinG Used 

aroUnd tHe installation to ensUre Heat toleranCes 

are CoMPatiBle. WHen tHe aPParatUs is in oPeration 

tHe area aroUnd tHe Model Gets Hot - Heat sensitiVe/

reaCtiVe Materials sHoUld not Be Used. do not PlaCe 

FlaMMaBle oBJeCts on or aroUnd tHe aPParatUs.

Appliances are not designed to incorporate doors or opening covers 

(unless specifically purchased as a resolved item from The Fire 

Company Pty Ltd). 

The appliance must remain open at all times for ventilation – it is not 

designed to operate as an oven or similar “hot box” – the flame must 

have a constant supply of air to operate and be able to circulate and 

distribute the heat effectively.

WarninG: do not oPerate WitHoUt tHe Glass WindsCreen

the appliance must be fully assembled before being operated. 

Failure to install (or removal of) glass panels will void the warranty 

and render the product unapproved for use with the included 

burner.

Summary of Contents for 1000SS

Page 1: ...g 195 1lbs ESF 1 F 1700SS 63 6kg 139 8lbs ESF 1 F 1500SS 45 1kg 99 2lbs WARNINGS If the information in this manual is not followed exactly a fire or explosion may result causing property damage person...

Page 2: ...front side of the flange or from the back of the flange screwed riveted or glued with a high temperature resistant bonding product onto the surrounding structural framework The floor must be level and...

Page 3: ...04 2017 The Fire Company Pty Ltd All rights reserved V081117 Fireplace Inserts Installation Before getting started ensure you have received all necessary parts 4 x Glass Spigots SCREW PIN Mount tube n...

Page 4: ...ppliance flange Premium Single Sided Fireplaces Installation 1 Construct main wall framework leaving an opening as dimensioned in Table A Table A Framing Dimensions Physical model dimensions should be...

Page 5: ...rate according to the Burner Operations Manual included with the burner Premium Single Sided Fireplaces Installation 25mm 25mm ASSEMBLE GYPROCK WALL PLANES ALLOW 25MM STAINLESS ST EDGE ALLOW 25MM STAI...

Page 6: ...TUNG NIEMALS OHNE GLASS WINDSCHUTZ WINDSCREEN ENTZ NDEN Die Firebox muss sicher und vollst ndig verbaut sein bevor diese in Betrieb genommen werden darf Ein fehlerhaft installierter oder komplett entf...

Page 7: ...den Kanten der Verschalung mit Silikon ab 4 Schieben Sie die Firebox in die Verschalung die Bodenwanne kann direkt auf der Betonschalung platziert werden 5 Fixieren Sie die Firebox durch die vorhanden...

Page 8: ...rivet s ou coll s avec un produit r sistant aux fortes temp ratures sur le pourtour de la structure Le sol doit tre de niveau et le syst me positionn sur une surface plane Le sol peut tre fait dans n...

Page 9: ...e ciment fix s au cadre MAX 8mm 0 3in 3 Siliconer tous les bords internes pour rendre la cavit tanche 4 Faites glisser la chambre de combustion l int rieur de la cavit le plateau inf rieur peut s asse...

Page 10: ...www ecosmartfire com EcoSmart EcoSmart The Fire Company...

Page 11: ...1 900SS 943 37 1 364 14 3 854 33 6 1000SS 1092 43 0 381 15 0 690 27 1 1200SS 1292 50 9 381 15 0 690 27 1 1500SS 1592 62 7 381 15 0 690 27 1 1700SS 1792 70 6 421 16 6 686 27 0 1800SS 1892 74 5 511 20 1...

Page 12: ...www ecosmartfire com EcoSmart Premium Single Sided Fireplaces Premium Single Sided Fireplaces FIREBOX EcoSmart...

Page 13: ...690 27 1 900SS 943 37 1 364 14 3 854 33 6 1000SS 1092 43 0 381 15 0 690 27 1 1200SS 1292 50 9 381 15 0 690 27 1 1500SS 1592 62 7 381 15 0 690 27 1 1700SS 1792 70 6 421 16 6 686 27 0 1800SS 1892 74 5...

Page 14: ...rmanence pour la ventilation il n est pas con u pour tre utilis comme four ou quipement de r chauffe autre que ce pourquoi il est pr vu la flamme doit tre en permanence au contact de l air pour pouvoi...

Page 15: ...la cavidad estanco 4 Deslice la caja de fuego dentro de la cavidad la bandeja inferior puede sentarse directamente en la parte superior de la placa de cemento 5 Fije la caja de fuego al marco estruct...

Page 16: ...Showrooms 3 4 40 42 O Riordan Street Alexandria NSW 2015 Australia Tel 61 2 9997 3050 Email info ecosmartfire com V081117...

Reviews: