WST-221 Wireless Recessed Contact 

 

Specifications 

Frequency: 319.5MHz  

 

 

Operating Temperature: 32°-120°F (0°-49°C) 

Battery: 3V lithium CR-2  

 

 

Operating Humidity: 5-95% RH non condensing 

Battery life: 5 years  

 

 

Compatible with GE/Interlogix receivers 

Magnet gap: 1 inch max 

 

 

Supervisory signal interval: 60min (approx.) 

 
Enrolling 

To enroll the sensor, set your panel into program mode, then go to the Learn Sensors menu. Refer 
to your specific alarm panel manual for details on these menus. To activate the case tamper 
simply slide the cover up and down, you will hear a click when the case latches are engaging and 
disengaging. Continue until the panel responds to the sensor. Then select the appropriate sensor 
group and number.  
 

Mounting 

The recessed sensor and magnet are designed to fit snuggly in a ¾ inch hole and a small flange on 
the outer rim ensures the case cannot be pushed too far into a hole. 
 
Choose a suitable location for the sensor, drill a ¾ inch by 2.5 inch hole in the door for the sensor. 
Mark the location for the magnet in the frame directly in line with the sensor and drill a ¾ inch by 
½ inch hole for the magnet.   
       

 
Installing /Replacing the Battery 

When the battery is low a signal will be sent to the control panel. To install/replace the battery: 
 
1.

 

Remove the cap on the transmitter. 

2.

 

Take note of how the circuit board fits into groves on the side of the case. 

3.

 

Carefully slide out the circuit board. 

4.

 

Inspect the battery holder to determine which side the battery is inserted/removed. 

5.

 

Install /replace with a CR-2 battery ensuring the + side of the battery faces towards the 
circuit board. 

6.

 

Re-insert the circuit board so that the board slides within groves in the plastics. 

7.

 

Once in, replace the cap. 

 

 

Note:

 Removing the cover will trigger a zone tamper signal to the control panel

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 