CS-222 Wireless Recessed Contact Sensor 

 

Specifications 
Frequency: 345 MHz  

 

 

Operating Temperature: 32°-120°F (0°-49°C) 

Battery: 3V lithium CR-2  

 

 

Operating Humidity: 5-95% RH non condensing 

Battery life: 5 years  

 

 

Compatible with Honeywell and 2GIG receivers 

Magnet gap: 1 inch max 

 

 

Supervisory signal interval: 60 min(approx.) 

 
Enrolling 
To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual 
for details on these menus. When prompted by the panel, trigger the sensor by moving the 
magnet in and out of range of the sensor. The panel will beep when you have successfully learned 
in a sensor. 
 
 
Mounting 
The recessed sensor and magnet are designed to fit snuggly in a ¾ inch hole and a small flange on 
the outer rim ensures the case cannot be pushed too far into a hole. 
 
Choose a suitable location for the sensor, drill a ¾ inch by 2.5 inch hole in the door for the sensor. 
Mark the location for the magnet in the frame directly in line with the sensor and drill a ¾ inch by 
½ inch hole for the magnet.   
       
 
Installing /Replacing the Battery 
When the battery is low a signal will be sent to the control panel. To install/replace the battery: 
 
1.

 

Remove the cap on the transmitter. 

2.

 

Take note of how the circuit board fits into groves on the side of the case. 

3.

 

Carefully slide out the circuit board. 

4.

 

Inspect the battery holder to determine which side the battery is inserted/removed. 

5.

 

Install /replace with a CR-2 battery ensuring the + side of the battery faces towards the 
circuit board. 

6.

 

Re-insert the circuit board so that the board slides within groves in the plastics. 

7.

 

Once in, replace the cap. 

 

 

Note: Removing the cover will trigger a zone tamper signal to the control panel

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 