Specifications
Technical Data
Unit
Inspexx SD mrk. II
Max. operational pressure
bar
5
Water flow inlet
l/min
50
Water flow outlet
l/min
50
Max. temperature for water
°C
40
Weight
kg
110
Dimensions W x H x D
mm
1330 x 1525 x 725
4. Use
4.1. Forseen use
The mixing station is used for mixing and delivery of
pre-diluted detergent for cleaning stations or other
types of outlets. Water and detergent are mixed by a
dosing pump.
It is very important that the operational staff reads this
user guide thoroughly prior to installation and start of
operation. Operation as laid down in the directions for
use will ensure an optimum level of hygiene in your
factory and a minimum level of repair work.
4.2. Unforseen Use
The unit must only be used for mixing of water and
detergents for use in professional cleaning stations -
all other use will be considered unforseen use!
5. Installation
5.1. Directions for mounting of the Inspexx SD
mrk. II unit
ATTENTION
1. The unit should be mounted in frost free rooms
only.
2. The unit is leveled by adjusting the feet. When
the unit is leveled the lock nuts on the feet are to
be tightened thoroughly.
3. The unit is fastened to the floor using a bolt
through the hole on each foot. It is sufficient to
fasten the feet in the corners.
5.2. Water connection
CAUTION
1. The unit must only be installed by skilled per-
sonell in this case Ecolab.
2.
Before the station is connected to the water sup
-
ply pipe, the supply line should be rinsed care-
fully in order to remove coarse impurities and
metal shavings.
3. The pressure loss in the supply line should be
held as low as possible by:
- avoid long supply pipes
- mounting of low pressure resistance ball valves and
- avoiding fittings with high pressure loss
4. When installing the piping, take care to avoid air
traps.
5. Max. supply water temperature: 40°C
Max. water supply Inspexx SD mrk. II:
50 l/min
Max. allowed inlet water pressure: 5 bar
5.3. Bleeding the pump
WARNING
Never start up the supply pump before
the pump has been bled.
When the unit has been mounted and water has been
connected to the inlet side, the pump must be bled.
This is done by opening the bleeding screw in the top
of the pump. Operate the valve for the dosing pump
and fill the tank with water and bled the supply pump.
The pump must be bled until only water comes out of
the pump.
Summary of Contents for Inspexx SD - Mrk. II
Page 1: ...Inspexx SD Mrk II Directions for use Gebrauchsanweisung Mode d emploi Instrucciones de uso...
Page 2: ......
Page 56: ......
Page 58: ...English EN Layout and Parts Inspexx SD mark II 11900460 1 58 English EN...
Page 65: ...110005503 9A 110005503 10 65...
Page 66: ...English EN Mounting Inspexx SD mark II 119000460 2 66 English EN...
Page 67: ......