![Ecolab EcoPro Operating Instructions Manual Download Page 170](http://html1.mh-extra.com/html/ecolab/ecopro/ecopro_operating-instructions-manual_2354523170.webp)
13.5
Electrical data
Name
Type
00510X
Type
01110S
Type
03003M
Type
05010M
Type
12003M
Supply voltage [V / Hz]
100 - 240 ±10% / 50/60
Motor power [W]
30
50
Degree of protection
IP65
Appliance class
II
Inputs:
Level, external release, batch
max. 24 V DC / 6 mA
Pulse, standard signal (0/4-20 mA)
Max. 25 mA (approx. 50 ohms)
Minimum pulse length (ON/OFF)
15 mS
Outputs:
Alarm (relay contact)
230 V, AC/DC, 3 A
Stroke signal (transistor)
Max. 24 V, DC, 200 mA
External power supply
5 V, max. 100 mA
Permissible cables:
Permissible external diameters for connecting the inputs/outputs:
AD Ø = 5.1-5.7 mm. LIYY 4 x 0.5; LIYY 5 x 0.34; LYCY 2 x 0.34
Permissible cable: Oilflex 4x0.5
13.6
Tightening torques
NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity of
the thread.
The tightening torques of the metering head screws are given on an adhesive
label that is affixed to the pump head.
Tightening torque of the suction/pressure valves:
Pump head size
5 l/h and 11 l/h
5 l/h and 11 l/h
5 l/h and 11 l/h
Tightening torque
2
±
0.2 Nm
2,8
±
0.2 Nm
4
±
0.2 Nm
Tightening torque of the metering head screws:
Pump head size
5 l/h and 11 l/h
5 l/h and 11 l/h
5 l/h and 11 l/h
Tightening torque
3,75
±
0.25 Nm
6
±
0.25 Nm
6
±
0.25 Nm
Technical specifications
78
417102264 Rev. 5-01.2019
Summary of Contents for EcoPro
Page 2: ......
Page 3: ...Ecolab Dynamic Pump EcoPro Betriebsanleitung EcoPro 417102264 Rev 5 01 2019 08 01 2019 GERMAN...
Page 365: ......
Page 459: ......