![ECOFOREST Atenas Installation And Maintenance Manual Download Page 27](http://html1.mh-extra.com/html/ecoforest/atenas/atenas_installation-and-maintenance-manual_2354364027.webp)
26
1.
PLEASE BEWARE THAT...
In order to prevent the risk of accident, a correct installation must be done following the instructions of this
manual. Your
ECOFOREST
distributor will be available to help you and provide you information related to codes,
assembly and installation norms in your area.
As ecoforest do not have direct control on the installation of your stove, ecoforest do not guarantee it and do
not bear the responsibility of any damage that could result from a bad use or a bad installation.
We carefully recommend the heat calculation to be made by a qualified heating engineer.
We recommend that a confirmed specialist sets up your pellets stove.
Maintenance work to be carried out at the end of the season or for every 500 kg of fuel burned, as well as
any repairs or equipment modifications, must be performed by authorized personnel.
Before getting started with the stove installation, please check section
4
.
2.
ADVICE AND RECOMMENDATIONS.
2.1.
All local regulations, including those referring to national and European standards must be met when
installing the stove.
2.2.
The stove must be installed on floors of sufficient bearing capacity and, if the existing construction does not
allow this, the floor must be adapted and made suitable, for example by fitting a load distribution plate.
1.3.
Never use petrol, fuel for lanterns, kerosene nor any similar liquid. Keep this kind of fuel away from your
stove.
2.4.
Do not try to turn on your stove if some glass is broken.
2.5.
Make sure the glass door of the fireplace is well closed while the stove is in operation; also check the
cleaning hatches (if you have touched them).
2.6.
Unauthorized modifications are forbidden. Use only spare parts provided by Ecoforest (see exploded view).
2.7.
Do not overload the stove; continuous heating efforts might cause premature aging and damage paint (it is
recommended not to exceed 250°C for gas outlet temperature).
2.8.
Do not use the stove as a burner.
2.9.
To prevent possible electrical shocks, only trained personnel should have access to the sides and the back of
the stove.
2.10.
In order to refill the stove with fuel, the user must open the hopper lid and empty the contents of the fuel
tank carefully, to prevent it from overflowing.
Drawing 1
2.11. FIRE IN THE EXHAUST.
To prevent this situation from happening, observe the instructions set forth under
section 4 on how to install the gas outlet. What to do:
The appliance will be turned off due to the excessive temperatures in the exhaust. Do not unplug the
stove.
Call fire brigade.
Tapa de la tolva.
Combustible.
Summary of Contents for Atenas
Page 1: ......
Page 111: ...110 9 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE EC UNE EN 14785...
Page 112: ...111 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECOAIRE INSERT EE UNE EN 14785...
Page 114: ...113 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS ECO II INSERT EAM UNE EN 14785...
Page 116: ...115 14 MEDIDAS MEASURES MESURES MISURES MEDIDAS ATENAS VR 2012 UNE EN 14785...