VERSION: v3.0
REVISION DATE: 12/2/22
INSTALLATION GUIDE
RATINGS
PAGE
06
TORQUE SPECIFICATIONS
*Class A System fire rating with Type 1, 2, and 29 PV modules with no skirt required. Class A System fire rating with Type 4 and 5
modules with south edge skirt required. Any roof-to-module gap is permitted. This rating is applicable with any roof attachment.
**Class B System fire rating with Type 4 and 5 modules, no skirt required. Any roof-to-module gap is permitted. This rating is
applicable with any roof attachment.
Fire Rating
Class A* and B** System Fire Rating
Max System Voltage
1500 VDC
Max Fuse Rating
40A
Certification
Conforms to UL STD 2703
Warranty
25 Year Material and Workmanship
UL 2703 Markings
Product listing label is located on the rail end-caps
Roof Pitch
2:12 – 21:12
UL 2703 Allowable Design Load Rating
10 psf downward, 5 psf upward, and 5 psf lateral
Max Module Size
25.6 sqft
Module Orientation
Portrait or Landscape
Multiple use Rated Components (Position Independent)
Mid Clamp, Frame MLPE Mount and MLPE Mount
UL 2703 MARKING EXAMPLE:
Component
Torque (in-lb)
Notes
Lag Screw
N/A
Fully Seat. Use visual indicator of the black EPDM ring around the
bonded washer for torquing.
Mid-Clamp
144
End-Clamp
96
Rail Clicker Leveling Bolt
142
Pre-torqued upon delivery. Applies to Tile Hook and L-Foot/Clicker
Hook Height Bolt
N/A
Lightly clamp hook to flush with top of next tile row
Ground Lug
N/A
Refer to specific ground lug manufacturer’s installation manual
MLPE Clip
144
MLPE Mount
144
CLICKFIT
SYSTEM
MFG ID CODE: SSS-QQ-YYYY
Conforms to UL STD 2703
XXXXXXX
RATINGS