A, Installation & Mounting: 

 
 

 
 

 
 

 

 

 
1, Installation Location: 

 
The thermostat should be mounted on an inner wall 1.5m above the floor in 

a position where it is readily affected by changes in the ambient room 
temperature. Prevent direct exposure sunlight and moisture. Do not place 
this unit where air circulation is low, or where it is susceptible to rapid 

temperature changes (e.g. near a door or window). Do not position near 
heating/cooling appliances. 

Caution: 

Turn off the ET1 and any electrical devices that are to be 

connected after installation. The installation must be carried 
out by a qualified electrician and conform to current IEE 

regulations.  

B, Battery installation / Replacement: 
 

Caution: Turn off electrical devices and disconnect the supply to any 
connected appliances before installing or replacing batteries. Replace only 

with the same (AAA Alkaline) or equivalent batteries. Do not dispose of used 
batteries with household waste. Refer to your local area for correct disposal 

method. 
 

 
1, Pull out the battery draw. 

2, Place new batteries taking note of 
    orientation of +/- on battery drawer. 

3, Dispose old batteries properly. 
4, Slide battery draw into position. 

5, Check operation and press reset  
    (RST) if not functioning correctly. 

 

(Figure 1) 

C, Setting Temperature:

 

- Adjust the temperature to your chosen set-point using the         or

 

buttons. 

- Ambient room temperature display will resume after 8 seconds and the  

   icon will disappear.  
 

 

D, Default Display Mode:

 

- Temperature detection starts and LCD displays the room temperature. 
- If the battery is LOW,        will be displayed. The batteries must be 

replaced immediately. 

- The defrost function is activated with       displayed when the temperature 

is 5

0

C or below. The output will switch ON automatically for heating & 

OFF if the ET1 is configured for cooling. 

- If the ambient temperature falls below 0

0

C the ET1 will display “LO”. 

- Above 40.5

0

C the ET1 will display “HI”. 

E. Jumper Selection:

 

 

- Heating, Cooling Jumper Bridge. 

When the jumper bridge is connected to “Heater” the heating 

configuration is selected. When the jumper bridge is connected to 
“Cooling” the cooling configuration is selected. The thermostat will not 

operate without a jumper connection existing. 
 

 

2, Wiring:

 

There are three terminals at the bottom of the ET1, labelled as 

“Com” (Common), “NO” (normally open) and “NC” (normally closed). 
Connect the appliance to the “NO” and “Com” terminals. Leaving the “NC” 

terminal empty. 

• 

Refer to the circuit diagram printed on rating label on the back of the 
product. 

• 

Push all wiring into wall prior to mounting to avoid trapping wires. 

• 

The thermostat should be protected by the fused spur supplying the 
heating system, using a fuse with a current rating no larger than 5A. 

 

 

 
 

3, Mounting: 

Mount the ET1 using the screw accessories provided through slots/holes on 

rear face of the unit. 

Mains 
Switching 




 

TABLE OF CONTENTS 

A. Installation and mounting 
1, Installation 

2, Wiring  

3, Mounting  

B, Battery Installation / Replacement  
C, Setting Temperature  

D, Default Display Mode  

E,  Jumper Selection  
F,  Normal Operation  

Page 