As the pictures show, the two square holes in the center of the base is the safety rope junction.
4. Using the safety cable which can withstand 10 times the weight of the equipment.
5. Make sure the X,Y protect locks are opened, Verify that within 0.5 meters there is no
combustibles .
6.3 EQUIPMENT CONNECT
Attention! One product only can accept one input and one output.
LM1915 has DMX input and output 3pin and 5pin connection socket.
Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin
3connected to the positive polarity signal.
DMX512 cable must use the professional shielded twisted pair cable; standard
loudspeaker cable is not reliable to control the long-range data. 24AWG cable is
suitable for more than 300 meters long-distance signal transmission and must add\
DMX 512 signal amplifier.
Do not use two outputs to separate the connection, if separate a continuous connection
to branch, DMX512 splitter is necessary.