background image

As the pictures show, the two square holes in the center of the base is the safety rope junction.   

 

           

 

4. Using the safety cable which can withstand 10 times the weight of the equipment. 

    5. Make sure the X,Y protect locks are opened, Verify that within 0.5 meters there is no 

combustibles . 

 

 

 

6.3 EQUIPMENT CONNECT

 

 

Attention! One product only can accept one input and one output. 

LM1915 has DMX input and output 3pin and 5pin connection socket.   

Pin 1, FOR GROUND; Pin 2 connected to the negative polarity signal; The pin 

3connected to the positive polarity signal. 

 

DMX512 cable must use the professional shielded twisted pair cable; standard 

loudspeaker cable is not reliable to control the long-range data. 24AWG cable is 

suitable for more than 300 meters long-distance signal transmission and must add\ 

DMX 512 signal amplifier. 

Do not use two outputs to separate the connection, if separate a continuous connection 

to branch, DMX512 splitter is necessary. 

Summary of Contents for LM1915

Page 1: ...Wash 19x15 Content ...

Page 2: ...4 Prevention of electric shock 06 4 5 To prevent burning or fire 06 5 Packing and Shipping 06 5 1 Attachment 06 5 2 About Device Package 07 5 3 Unpacking 07 6 Installation Standards 07 6 1 Rigging Installation 07 6 2 Equipment Fixed 07 6 3 Equipment Connection 08 6 4 Cable Connection 09 7 AC Power 09 7 1 Voltage Fuse Specification 09 7 2 Power Connection 10 8 Control Panel Operate 11 ...

Page 3: ...s due to misuse and the neglect of this operating manual will be excluded from the deal responsibility this manual will not informed in additionally if have technical changes About the latest software hardware documents and other information please log in our company website 1 Production Introduce Thank you for choose this LM1915 products this model is the newest led moving head light which is the...

Page 4: ...tor and setting sound master slave control mode can do rainbow variable strobe and electric dimming effect LM1915 has quick response speed seismic impact resistance good heat dissipation Long using life the life of the LED is over 100000 hours no radiation high efficiency and energy saving low energy consumption the real green products Accept international DMX512 signal mode LM1915 applications ve...

Page 5: ...come into contact with water or any other liquid The use of this product should pay attention to fire heat electric shock ultraviolet radiation the lamp to explode or Shedding caused serious or fatal injury Please read the instructions before use energized or installing Follow through the operation of security methods and pay attention to the warning signs on the specification and equipment 4 1 AN...

Page 6: ... sure you use the power voltage lamps must comply with the identified power voltage and have an overload or leakage protection Each fixture must be properly grounded installed in accordance with the relevant standards Cut off the power when stall or replace the lamp and the fuse Forbid using the fixture in storm or wet environment 4 5 TO PREVENT BURNING OR FIRE 1 The fixture can t be mounted direc...

Page 7: ...he equipment suitable environment temperature range is 0OC 40OC don t use it in too high or too low temperature When the equipment is on installation dismounting removing or repairing please don t stay in the right below of the fixture The operator must ensure that the fixture is a secure connection Please let professionals to check its electrical parameters before installation Make sure the relat...

Page 8: ...M1915 has DMX input and output 3pin and 5pin connection socket Pin 1 FOR GROUND Pin 2 connected to the negative polarity signal The pin 3connected to the positive polarity signal DMX512 cable must use the professional shielded twisted pair cable standard loudspeaker cable is not reliable to control the long range data 24AWG cable is suitable for more than 300 meters long distance signal transmissi...

Page 9: ...use the manufacturer or its service agent offered Connect the DMX data from the controller to the nearest controller equipment 3pin or 5pin socket and then from this equipment output connected to the next equipment input like this continuous connecting finally the output of the terminal equipment for the data cable insert a terminal plug If use DMX512 distributor the controller connect to the DMX5...

Page 10: ...ter press it will execute orders accordingly 3 Can change the parameter Settings directly on the touch screen 4 Also can use the wheel on the left side of touch screen to change the parameter Settings 5 Can use the built in battery by the left button of touch screen change the parameter Settings When using the built in battery for power supply the green Indicator lights up 6 The equipment have bui...

Page 11: ...e Total Tim 00048 00 WorkHour 00000 03 Times 0000 61 ClearTim ClearTim Touch Screen_Control Vtft 01 Software version XY _Control Software version LED _Control Software version Return Control Channel 01 25 64 Channel 02 50 127 Channel 03 100 255 Channel118 25 64 Channel119 50 127 Channel120 100 255 Display ShowReve Natu Revl Language Chin Engh BrigSett 0 100 Backligh Ligh 90s MenuBack Off 60s Retur...

Page 12: ...master slave mode control function 11 Many strobe and rainbow effect 12 With rich built in single control settings program every color and gobo can be adjusted Red 255 Green 255 Blue 255 White 255 Every background color of the built in program can be adjusted Red 255 Green 255 Blue 255 White 255 13 By using constant current control of each color its brightness maintain on the same level no matter ...

Page 13: ...Channel5 0 255 Blue darkest brightest Channel6 Channel6 Channel6 0 255 Blue Fine Channel7 Channel7 Channel7 0 255 White darkest brightest Channel8 Channel8 Channel8 0 255 White Fine Channel9 Channel9 Channel9 0 255 Color temperature control Channel10 Channel10 Channel10 Colour macro 1 4 Colour macro off 5 9 Colour1 White 10 14 Colour2 DirtyWhite 15 19 Colour3 AliceBlue 20 24 Colour4 DarkSteelBlue ...

Page 14: ...190 194 Colour36 SunriseRed 195 199 Colour37 DarkAmber 200 204 Colour38 MediumAmber 205 215 ColourForward Jump Fast Slow 216 228 ColourForward Jump stop 229 239 ColourForward Jump Slow Fast 240 245 Random Colour Slow speed 246 250 RandomColour Mid Speed 251 255 RandomColour Fast Speed Channel11 Channel11 Channel11 Strobe 0 19 No strobe 20 49 Strobe ON 50 64 Conventional Strobe Fast Slow 65 69 Stro...

Page 15: ...el22 0 255 Auto program selection Channel23 Channel23 0 255 Auto program speed setting Channel24 Channel24 0 255 Auto program fade in Channel25 Channel25 0 255 Auto program Red Channel26 Channel26 0 255 Auto program Green Channel27 Channel27 0 255 Auto program Blue Channel28 Channel28 0 255 Auto program White Channel29 Channel29 0 255 Auto program Focus Channel30 Channel30 0 255 Backlight dimming ...

Page 16: ...nance LM1915 need do daily cleaning and maintenance the equipment life time is greatly depends on the operating environment please consult the technical department for professional advice submit the repair and maintenance to the professional technician Attention Too much dust smoke flow the damage by unnormal use are not covered under ...

Page 17: ... or pressure blow down gently blowing off the dust 3 With No bouquet cotton paper or using cotton cloth with water or distilled water to wipe the granular material do not wipe the surface use the pressure gas blow away the dust 4 with dip with ethylene propylene glycol cotton cloth or No smell of cotton paper to remove the dust and residues also can use glass cleaner but must use distilled water t...