3.4 COMPONENTS 

EVERLUX  light  source  includes  the  following  components.  It  is  recommended  to  identify  and 
check their existence before proceeding with the installation. 

  Main Unit   

  Power Supply Cable 

 

User’s Manual 

4.  INSTALLATION AND SET UP 

Experienced or expert personnel are not required to install the EVERLUX.  

 Once  the  installation  is  over,  please  continue  with  the  procedures  detailed  in  the  Revision 
section. 

Thoroughly follow the instructions included in this section. 

 

1)  Unpack the equipment carefully. 
2)  In case of using the EVERLUX as an endoscopic light source, place it on a solid and flat 

surface. 

3)  Rotate  the  universal  adapter  until  the  corresponding  connector  is  aligned  with  the  light 

output. 

4)  Connect  the  fiber  optic  cable  to  the  corresponding  connector  of  the  universal  adapter 

(depending on the fiber optic to be used). The fiber optic connector shall match perfectly 
and not exceed the adapter. 

5)  In  case  of  using  the  EVERLUX  as  a  Microscope  /  Colposcope  light  source,  mount  the 

EVERLUX  on  the  Ecleris  Microscope  /  Colposcope  forearm  (See  “Light  Source 
Installation” Section in Ecleris Microscope /Colposcope User’s Manual) 

6)  Rotate the universal adapter until the Wolf connector is aligned with the light output. 
7)  Connect the fiber optic cable to the Wolf connector of the universal adapter. The fiber optic 

connector shall match perfectly and not exceed the adapter. 

When turning the light source on, check fans functioning. 

If  due  to  any  breakdown  they  do  not  work,  turn the  equipment  off  immediately  to  avoid 
failures in the LED system as a result of high temperature. 

The EVERLUX shall only be used in places with electrical installations that meet the local 
regulations in effect. 

It shall always be connected to the grounding of the operating room or endoscopy tower 
through a ground cable. 

The  EVERLUX  shall  be  connected  to  the  voltage  line  through  the  power  supply  cable 
provided. 

The power supply shall only be provided with a protected plug and the adequate ground 
connection. 

 

Summary of Contents for EVERLUX

Page 1: ...ut previous written authorization from ECLERIS Neither can it be reproduced multiplied or published through any electronic data processing form The information contained in this manual may be modified...

Page 2: ...3 2 INTENDED USER 5 3 3 FEATURES AND DESCRIPTION 5 3 3 1 FRONT PANEL 5 3 3 2 REAR PANEL 5 3 4 COMPONENTS 6 4 INSTALLATION AND SET UP 6 4 1 REVISION 7 5 OPERATION FUNCTIONS 7 6 MAINTENANCE 7 6 1 CLEAN...

Page 3: ...recautions Please read the manual thoroughly before operating the equipment Should you have any doubt regarding the contents of the manual herein or the equipment operation and safety please contact y...

Page 4: ...blem the system must be laid a plane surface and power cable disconnected The device must be used only by personnel informed of all this warnings Any use outside of the manufacturer specific intent us...

Page 5: ...its use for all types of procedures The EVERLUX allows the connection of the Ecleris PROCAM universal endocamera which has a 1 3 CCD sensor and integrated controls especially designed for medical appl...

Page 6: ...l match perfectly and not exceed the adapter 5 In case of using the EVERLUX as a Microscope Colposcope light source mount the EVERLUX on the Ecleris Microscope Colposcope forearm See Light Source Inst...

Page 7: ...S office prior to its use 5 OPERATION FUNCTIONS This section thoroughly describes the device functioning This system must be used only for medical paramedical or health professionals 1 Connect the pow...

Page 8: ...following the instruction provided by their manufacturer Do not turn the light source on until an hour 1 has passed from the cleaning since the unit can get damaged It is recommended to clean the exte...

Page 9: ...UT Composite video CVBS 1 Vpp 75 BNC S Video Y C Jack mini DIN ECLERIS ENDODIGI CONNECTOR Jack 3 5mm mono DIMENSIONS 120x300x155mm width x depth x high MASS 7 7 pounds SERVICE CONDITIONS 50 104 F 35 7...

Page 10: ...Lateral ventilation grids are obstructed Clear the lateral ventilation grids Fan is not working Turn the equipment off immediately and contact the closest Technical Service Light is correct but no im...

Page 11: ...blem description The shipment should be done in the original packaging to avoid damage to the equipment during the transportation ECLERIS will not be responsible for damage caused during the transport...

Reviews: