Ecler VEO-MXH44 User Manual Download Page 4

 

 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 
other apparatus (including amplifiers) that produce heat. 

 

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 
polarized plug has two blades with one wider than the other. A grounding type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong  are  provided  for  your  safety.  If  the  provided  plug  does  not  fit  into  your 
outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect  the  power  cord  from  being  walked  on  or  pinched  particularly  at  the 
plugs,  convenience  receptacles,  and  at  the  point  where  they  exit  from  the 
apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods of 
time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 
apparatus has been damaged in any way, such as power supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or 
has been dropped.

 

14.

 

Disconnecting  from  mains:  Switching  off  the  POWER  switch  all  the  functions 
and light indicators of the amplifier will be stopped, but fully disconnecting the 
device  from  mains  is  done  unplugging  the  power  cord  from  the  mains  input 
socket. For this reason, it always shall remain readily operable. 

15.

 

Equipment is connected to a socket-outlet with earthing connection by means of 
a power cord. 

16.

 

The marking information is located at the bottom of apparatus. 

17.

 

The apparatus shall not be exposed to dripping or splashing and that no objects 
filled with liquids, such as vases, shall be placed on apparatus. 
 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class 

A  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 
operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction 
manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense.  

 

WARNING

:

 

This product must not be discarded, under any circumstance, as 

unsorted  urban  waste.  Take  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

NEEC  AUDIO  BARCELONA,  S.L. 

accepts  no  liability  for  any  damage  that  may  be 

caused to people, animal or objects due to failure to comply with the warnings above. 

Summary of Contents for VEO-MXH44

Page 1: ...v 20200406 VEO MXH44 VIDEO MATRIXES HDMI 2 0 4X4 18GBPS Matrix with Audio De embedders USER MANUAL ...

Page 2: ... WEB CONTROL 9 9 1 Connecting your PC to VEO MXH44 9 9 2 Port Set page 10 9 3 EDID Config page 10 9 4 IP Config page 11 10 RS 232 and TCP IP CONTROL FOR THIRD PARTY 11 10 1 Command strings list 12 11 CONTROL CENTER UTILITY 14 12 1 Software Connection 14 12 2 RS 232 connection 14 12 3 Network connection 15 12 4 Port Set Page 16 12 5 EDID Config Page 17 12 6 IP Config Page 17 12 7 System Config Page...

Page 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Page 4: ...ifier will be stopped but fully disconnecting the device from mains is done unplugging the power cord from the mains input socket For this reason it always shall remain readily operable 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of apparatus 17 The apparatus shall not be exposed to dripping or s...

Page 5: ...ls with bandwidth up to 18 Gbps It is the ideal solution for applications requiring 4K UHD and HDR sources and displays VEO MXH44 includes analogue audio de embedding feature and EDID management The HDMI selection can be manual via frontal panel or remote via serial commands TCP IP and IR The integrated web GUI allows to configure and control the unit in a very user friendly way Features 4x4 Ultra...

Page 6: ... 6 PANEL DESCRIPTIONS 6 1 FRONT PANEL 1 IR receiver Infrared sensor for remote control 2 Input selection LED indicator It provides information about the current HDMI Input selected 3 Selection button It allows changing the HDMI input selection for each HDMI output Note Turn ON OFF DHCP function press for 3 seconds select buttons from OUTPUT 1 and OUTPUT 2 ...

Page 7: ...ated HDMI output 2 HDMI 2 0 Input Ports 3 IR port for External IR receiver 3 5mm Minijack to connect the external remote IR sensor included 4 4 HDMI 2 0 Output Ports 5 5 RS 232 Port For serial remote control and or firmware update 6 Reserved Micro USB Port Service port for firmware update purpose 7 RJ45 for LAN connection and IP Web remote control 8 5V DC Power Connector ...

Page 8: ...d IR Remote please connect the IR Receiver to the corresponding port 8 IR REMOTE CONTROL 1 Stand by Mode 2 Output Input selection buttons In order to route INPUT Y to OUTPUT X press OUTPUT X X is output 1 to 4 and press INPUT Y Y is input 1 to 4 3 All Outputs selection button In order to route INPUT Y to all outputs press ALL and press INPUT Y Y is input 1 to 4 4 Cancel button It allows to cancel ...

Page 9: ...ontrol Panel Network and Sharing Center 2 Click Change Adapter Settings 3 Highlight the Internet Protocol Version 4 option and double click to change settings use a IP on the same network of the matrix 4 Click OK to confirm Once that your PC is in the same network of the VEO MXH44 open your Internet browser and digit 192 168 1 168 to visualize the control webpage ...

Page 10: ...this page it will be possible to set all the EDID options both for Video and Audio formats Note Analogue audio outputs are active only when 2CH is selected When other formats are selected the multi channel audio is passing through the HDMI and the analogue output will be muted ...

Page 11: ...ms via serial commands through the RS 232 Euroblock port on the rear panel or via LAN using a TCP IP connection Default Serial Settings Baudrate 115200 bps Data Width 8bit Parity None Stop 1 bit Default Network Settings Default IP 192 168 1 168 TCP IP port 5000 Note The end of line command is CR or LF chars are not required ...

Page 12: ...01 03 Source Selection on Output 3 Input 1 W 02 00 Input 2 W 02 01 Input 3 W 02 02 Input 4 W 02 03 Source Selection on Output 4 Input 1 W 03 00 Input 2 W 03 01 Input 3 W 03 02 Input 4 W 03 03 Read Source on Outputs Output 1 R 00 Output 2 R 01 Output 3 R 02 Output 4 R 03 PTP Function Input N to Output N W 04 00 01 02 03 Reboot Function W 50 Factory Reset W 51 Stand by Stand by ON W 0F 00 Stand by O...

Page 13: ...4K 60Hz 4 2 0 03 4K 60Hz 4 4 4 BB identifies the following functions HDR 48bit 36 bit 30 bit 7 1 CH 5 1 CH 2 0 CH 3D Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Active 1 1 1 1 1 1 1 1 Inactive 0 0 0 0 0 0 0 0 E g 11001001 HDR 48Bit 7 1CH 3D Convert Binary code 11001001 to hexadecimal format C9 E g W05 03 C9 The EDID of input 1 is 4K 60Hz 4 4 4 HDR 48Bit 7 1CH 3D ...

Page 14: ... 2 RS 232 connection After pressing Search button on COM Setting the software will automatically detect the first COM port available on your operating system in alternative it is possible to select the port manually Once the right COM port is selected after pressing Connect button the settings in use are read by the software and it will be possible to control the matrix ...

Page 15: ... Control Center Current PC information shows the IP address in use by the PC and allows to set the TCP IP used by the software to receive commands If there are no particular network needs use the default 5001 port Press Connect button and Search Device ...

Page 16: ... network range the unit will be discovered and the IP address will be shown as follows After pressing Connect on Host Device Information the software will be online and ready to control the matrix 12 4 Port Set Page Matrix switching control page ...

Page 17: ...and Audio formats Note Analogue audio outputs are active only when 2CH is selected When other formats are selected the multi channel audio is passing through the HDMI and the analogue output will be muted 12 6 IP Config Page On this page you can modify the network settings or activate the DHCP function ...

Page 18: ...guration page give the access to functions like Reboot Factory Default and Power ON OFF Furthermore using the command line available on this page it will be possible to test the commands mentioned on chapter 9 for third party control systems ...

Page 19: ... 2 1 4 Compliant Audio Formats PCM 2Ch LPCM 5 1 LPCM 7 1 Dolby Digital DTS 5 1 Dolby TrueHD DTS HD Master Audio Dolby Atmos Sample Rate 32kHz 44 1kHz 48kHz 88 2kHz 96kHz 176 4kHz 192kHz Bit rate up to 24 bit Distance HDMI up to 10 meters with Ecler VEO cables Operating Temperature 5 C 45 C 23 F 113 F Humidity 20 90 RH no condensation Power Consumption 13 W MAX Supply Input AC100 240V 50 60Hz Outpu...

Page 20: ...ght to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on our website in Support Technical requests Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...

Reviews: