11
5.6. Programming and control Ethernet port
The RJ45 connector labelled ETHERNET allows the connection of the equipment to an
Ethernet local network (LAN), being compatible with the following purposes:
•
Management from the EclerNet Manager application, by direct connection (CAT5 cable
or higher) of a computer with a MIMO7272DN unit or using an Ethernet network as a
link between both. Refer to the EclerNet Manager Application manual for more
information.
•
Connection to third party control equipment. (Crestron, AMX, Extron, Medialon, etc. are
registered brands from their respective owners). Protocol used: Ecler TP-NET. Refer to
the TP-NET protocol manual for more information.
•
UCP: EclerNet project remote control service using customisable graphical control
panels. MIMO7272DN can act as a server for these panels, included in an EclerNet
project, and also be remotely controlled by UCP panel client devices (WPNETTOUCH,
Android® or iOS® mobile devices, Windows® devices, etc.).
5.7. Control remote RS-232 port
The RS-232 port with DB9 connector built into the rear panel allows an external device
to communicate with a MIMO7272DN unit via serial connection. This connection will use
the syntax of the TP-NET protocol so that the external device can obtain the value of
some of the parameters of the MIMO7272DN unit (by means of "GET" commands) and/or
modify these values ("SET" commands). Refer to the TP-NET protocol manual for more
information.
The serial connection must comply with the following characteristics:
Baud rate: 115200 (fixed, no auto negotiation)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None