INSTALLATION
5.1. Location, assembly and ventilation
MIMO4040CDN has been specially designed to be placed in 19" rack structure, occupying
one unit.
It is very important that, as a heat generating element, MIMO4040CDN is not completely
enclosed or exposed to extreme temperatures. Fresh air should be allowed to pass
through the ventilation holes in the chassis, leaving at least one free rack unit between
each piece of equipment and those installed above and below it in the rack frame.
If the installation consists of several amplifiers in the same rack or is carried out inside
cabinets closed by means of doors, it is highly recommendable to equip them with forced
upward ventilation, installing fans at their lower and upper ends. This upward flow of
ventilation will favor the dissipation of the heat generated in its interior.
5.2. Mains connection and power on
MIMO4040CDN operates on alternating voltages from 90 to 264V and 47 to 63 Hz. This
device is equipped with an oversized power supply capable of adapting without any type
of adjustment to the mains voltage of any country in the world.
On the rear panel, next to the IEC power connector, there is an on/off switch for the unit.
On the front panel there is an LED indicator that illuminates when the unit is in operation.
Do not allow the network cable to run parallel to the shielded cables carrying the audio
signal, as this may cause humming.