LOCATION, ASSEMBLY AND VENTILATION 

Vida series devices have a 19" rack format (2RU). 

It is very important not to enclose the amplifier or expose it to extreme temperatures as it 
generates heat. 

It is also necessary to promote the passage of fresh air through the 

ventilation holes of the chassis

. The ventilation system forces the air flow, front to back, 

through the unit. 

If multiple products are installed in the same rack or in a cabinet with closed doors, it is 
highly recommended to install fans in their upper and 

lower ends for a forced airflow from the bottom up. This  upward air flow will help to 
dissipate the heat generated inside. 

It is advisable 

not  to  place  power  amplifiers  under  other  appliances

, but upon 

these ones, leaving at least one rack unit off between each device and installed above and 
below it in the rack frame. 

4.2

 

MAINS CONNECTION 

VIDA operates on alternating voltages from 90 to 264V and 47 to 63Hz. This device is 
equipped  with  an  oversized  power  supply  capable  of  adapting  without  any  type  of 
adjustment to the mains voltage of any country in the world. 

On the 

rear panel

, next to the IEC power connector, there is an 

On/Off

 

switch

 for the unit.  

 

On the 

front panel

 there is button 

ON/SLEEP

 with its LED indicator, that illuminates when 

the unit is in operation, and soft-blinks when it is in sleep mode. 

 

Do not allow the mains cable to run parallel to the shielded

 cables carrying the 

audio signal, as this may cause humming. 

Summary of Contents for Dante VIDA-24Q

Page 1: ...50 0429 0100 VIDA 24Q EN VIDA 24Q AMPLIFIERS Digital Amplifiers USER MANUAL PACKAGE CONTENTS FEATURES INSTALL CONNECT TECHNICAL DATA PANEL FUNCTIONS START UP OPERATION PRECAUTIONS...

Page 2: ...logue Input Connections 8 4 4 Player and Micro SD Card 8 4 5 Digital Audio Inputs and Outputs 9 4 6 Amplified Output Connections 9 4 6 1 OUT MODE 9 4 6 2 Operation Example 10 4 7 Auxiliary Output Conn...

Page 3: ...of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING A device with Class I construction shall be connected to a mains socket ou...

Page 4: ...when unused for long periods of time 13 Refer all servicing to qualified personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid...

Page 5: ...s an asymmetrical power distribution and thanks to the Smart VersaPower tool it helps installers by facilitating a smart and fast configuration In addition the Class D amplification technology as well...

Page 6: ...ground resistance Rg 30 Ohm or less The environment must be dry and dustless Do not expose the unit to rain or water splashes and do not place liquid containers or incandescent objects like candles o...

Page 7: ...p This upward air flow will help to dissipate the heat generated inside It is advisable not to place power amplifiers under other appliances but upon these ones leaving at least one rack unit off betw...

Page 8: ...onnection short circuit pin to pin 4 4 PLAYER AND MICRO SD CARD VIDA integrates a stereo audio player able to play audio files from local storage device microSD card for background music or voice mess...

Page 9: ...oller For more information please refer to the developer s documentation www audinate com products software dante controller 4 6 AMPLIFIED OUTPUT CONNECTIONS The rear panel is fitted with two position...

Page 10: ...inferior to 2 5mm2 and for superior distances 4mm2 4 7 AUXILIARY OUTPUT CONNECTIONS VIDA rear panel provides two analogues balanced line level auxiliary outputs Their independent routing mixing and p...

Page 11: ...ork groups including general volume Also loading presets or playlists Please refer to the web application manual for more information on www ecler com 4 8 1 CONNECTING THE GPI REMOTE CONTROL PORTS The...

Page 12: ...panel In this way it is possible to interact with external equipment such as motors for projection screens or movable partition walls lights sirens GPI inputs from other equipment etc 4 10 EXTERNAL MU...

Page 13: ...lock synchronization calendar events automatic firmware updates and other tools Reception of 4 channels of digital audio Dante and sending of 4 channels of digital audio Dante Connection of third part...

Page 14: ...mary Net1 incorporates Dante redundancy Recommended when using Dante with redundancy in two isolated LANs 4 Switch Mode ethernet ports perform as a 2 port switch and support control Dante Primary traf...

Page 15: ...of them fails VIDA will automatically switch to the other recovering the audio transmission almost instantaneously Obviously to achieve total redundancy all Dante devices that are part of a system of...

Page 16: ...ode both ports primary and secondary should never be connected simultaneously to network switches as this would create a loop that would cause network conflicts and disruption of the digital audio Dan...

Page 17: ...dicator LED 8 Thermal indicator LED 9 Dante indicator LED 10 Data indicator LED 11 On Sleep indicator LED 6 2 REAR PANEL 1 Power switch 2 Mains socket base 3 Amplified outputs OUT1 4 2 pin Euroblock P...

Page 18: ...type 2 pin Euroblock Pitch 7 62 mm Ref DEGSON 5EDGRC 7 62 Output configuration Lo Z Hi Z 70V 100V 4 8 2 Output mode selection per channel Rear panel DIP SWITCH selectors VERSAPOWER SYMMETRICAL All cha...

Page 19: ...Universal regulated SMPS with PFC AC mains requirement 100 240 V 50 60Hz 10 Power factor correction 0 96 AC mains connector IEC C14 inlet POWER HEAT 230VAC 1 4 POWER 4 Power 848 W 888 VA Current Draw...

Page 20: ...Efficiency 72 Cooling Fan Maximum fan noise 45dB PROTECTIONS DC protection Yes HF protection Yes Short circuit protection Yes Clip limiter Yes Long term limiter Yes Thermal protection Yes REMOTE CONTR...

Page 21: ...puts processing Delay Parametric EQ Graphic EQ independent for every amp out and aux out Limiters independent for every amp out Smart VersaPower management Others Preset management Internal matrix pri...

Page 22: ...ge humidity 5 85 RH non condensing Installation options Rack 19 installation desktop Included accessories Universal Main cords Euroblock Connectors inputs outputs Desktop feet rack 19 installation har...

Page 23: ...23 PACKAGE CONTENTS FEATURES INSTALL CONNECT TECHNICAL DATA PANEL FUNCTIONS START UP OPERATION PRECAUTIONS T O C...

Page 24: ...on tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your...

Reviews: