24
•
In the case of the CA40/CA120, there are just two possible string values for
this parameter:
o
INPUTS
o
PRESETS
•
•
And three in the case of the CA200z:
o
OFF
o
INPUTS
o
PRESETS
•
In the CA40/CA120, a single REMOTE port admits the connection of a
WPmVOL-SR
unit, which has a volume control knob and a 5-position rotary
switch, or selector. The selector can be used in any of these two modes:
o
INPUTS: to select the active audio source(s) (LINE1, LINE2, MICRO
(MICL3 for the CA120), LINE1_AND_MICRO (LINE1_AND_MICL3 for the
CA120) or LINE2_AND_MICRO (LINE2_AND_MICL3 for the CA120))
o
PRESETS: to recall any of the 5 presets in the memory of the unit, which
store the full configuration of the unit, including volumes, EQ, etc.
•
The factory default working mode of the selector is
INPUTS
, and it can just
be modified to
PRESETS
by means of an RS-232 connection.
•
•
In the CA200z there are two independent REMOTE ports, each one able to
control one of the device’s outputs when the CA200z has been configured in
the ZONES A/B mode. Each selector can be used in any of these 3 modes:
o
INPUTS: to select the active audio LINE source (OFF, LINE1, LINE2, LINE3
or LINE4)
o
PRESETS: to recall any of the 5 presets in the memory of the unit, which
store the full configuration of the unit, including volumes, EQ, etc. Just
one out of these two remote ports can be configured to recall presets,
not both at the same time
o
OFF: REMOTE port disabled.
•
<Zone>
are text strings (without blank spaces) that identify a zone where the
command will operate. In the CA200z there are just two possible values for this
parameter:
o
ZA (output labeled as ZA or L)
o
ZB (output labeled as ZB or R)
•
When the <Zone> parameter is not specified, the CA200z will understand
the command will operate over ZA.
•
<Micro Name>
are text strings (without blank spaces) that identify the MIC inputs
in the unit. In the CA200z there are just two possible values for this parameter:
o
MICRO1
o
MICRO2