Abbildung 47:
Figure 47:
The empty program block
9.4.2
General instructions for the address mapping of IO modules
9.4.2.1
Limitations of FBM modules
Note
CAN-Modules can only be located from byte address 128 or word address 64 onwards.
9.4.2.2
General instructions for the PLC configuration with LBM modules
All used LBM modules must have entries in the CoDeSys PLC configuration. The following
modules, that are automatically handled by the controller, are excluded:
• Analog axes, that are realized with LBM ARI01 modules for CNC or motion applica-
tions.
• Communication interfaces that are realized with LBM SER02 modules.
Modules, that have no corresponding entry in the PLC configuration, are ignored by the
controller. The LIFE-LED stays unlit. The process image isn‘t updated and the outputs stay
switched off.
Example for a PLC configuration with LBM modules: