17 / 97
Introduction Manual ENC66
eckelmann.de
1.4.3
Status information during start of firmware
The firmware is started after booting. The following indications are made in this phase.
Tabelle 9:
Table 9:
7-segment indicator, Status information during start of the firmware, ENC66
7-segment indicator
Meaning
0
Initialization of processor
1
Initialization of software
2
Initialization of operating software
3
Initialization of task and mailbox
4
Initialization of I2C hardware
5
Initialization of file system
6
Initialization of local bus
7
Hardware check
Flashing light of segment
Normal state acc. to description in /A/
Continuous error number
Error state acc. to tables in chapter 1.4.6.1