5.2 Temperature zones
The case controller supports up to 2 temperature zones, which can be configured via the "Temperaturzonen"
parameter (menu 6-1). The two UA 400 E CC / UA 410 E AC case controllers support single-zone
and
two-
zone operation. The UA 401 E CC variant only supports one temperature zone.
Single-zone operation
- UA 400 E CC / UA 401 E CC / UA 410 E AC
one temperature zone
one pilot case
In single-zone operation, the second E-valve is controlled with the same opening degree at a different time
than the first E-valve ("tandem operation", only UA 400 E CC / UA 410 E AC). Only the first five sensors and
only the setpoints of the first zone are included for the regulation.
For the room controllers, the setpoint for the heating circuit must be set to "– " in single-zone operation
so that tandem operation is possible.