Equipment Installation
XDM-300 Installation and
Maintenance Manual
3-26 ECI
Telecom
Ltd.
Proprietary
417006-2311-0H3-A00
To install the xRAP-100:
|
Attach the xRAP-100 to the rack side rails in the top position, and secure it
with the four screws, washers, and nuts supplied in the installation parts kit.
To ground the xRAP-100:
1.
The xRAP-100 grounding stud is located on its bottom cover. Use the
following figure to identify it.
2.
If necessary, prepare a grounding lead in accordance with the requirements
described in Grounding Requirements (on page
).
3.
Connect the lug at one end of the grounding lead to the xRAP-100
grounding stud using a spring washer and nut.
4.
Connect the lug at the other end of the grounding lead to the rack
grounding stud.