NPT-1020 Installation and Maintenance Manual
Maintenance
ECI Telecom Ltd. Proprietary
7-3
To use the troubleshooting table:
1.
Identify the closest description of the trouble symptoms under “Symptoms”.
2.
Perform the required corrective actions listed under “Corrective actions” in the order they appear,
until the trouble is corrected.
7.4.1
Troubleshooting Power Problems
Table
7-2: Troubleshooting power problems
No.
Symptoms
Probable cause
Corrective actions
1
RAP POWER ON
indicator off
Both main and backup power
sources failed
Check the site power distribution
system.
Check the DC voltage at the main
and backup power terminals of the
RAP.
If the voltage is not within the
correct range, check cable
connections up to the DC power
distribution panel and make sure no
fuses are blown.
Check the voltage supplied by the
main and backup power sources.
Check the power connections to the
RAP.
Check the circuit breakers in the
RAP and replace if necessary.
Equipment problem
Check the voltage at the NPT-1020
and EXT-2U end of each power
cable. Replace the cable or repair
the RAP if there is no voltage
present.
Check and reconnect cables to the
equipment, one by one. If the circuit
breaker trips again when connecting
a specific unit, replace that unit.