SRM-410X
MAINTENANCE
X7502168400
37
© 11/20 ECHO Incorporated
1.
Close choke (COLD START
position). This prevents dirt
from entering the carburetor
throat when the air filter is
removed. Brush accumulated
dirt from air cleaner area.
2.
Remove air filter cover (A).
Brush dirt from inside cover.
3.
Remove air filter (B) from case.
Use care to prevent dirt and
debris from falling into case.
4.
Inspect filter element and seal.
Replace filter if any of these
problems are present:
• Air filter seal does not fit tightly against case
• Air filter seal is distorted, worn, or damaged
• Air filter element has holes or other damage
• Air filter element is saturated with dirt
• Air filter element is soaked with fuel mix
5.
If air filter is in good condition and can be cleaned and reused, lightly
brush debris from air filter element, or blow filter element clean using
low pressure (40 psi or less) compressed air directed at inside of filter.
When using compressed air, always direct air stream at inside
surface of filter so dust and debris will be blown out of filter. Keep air
nozzle 6 - 8 inches away from filter to prevent damage to filter.
6.
Install air filter in case, and replace cover.
Fuel Filter
Level 1.
Parts Required: Tune Up Kit.
A