OPERATION
SHC-2620 / S
22
X7502342003
© 07/19 ECHO Incorporated
1.
Stop Switch
Move stop switch (A) away
from the STOP position.
2.
Choke
Move choke (B) to Cold Start
(closed) position.
3.
Purge Bulb
Pump purge bulb (C) until
fuel is visible and flows freely
in the clear fuel tank return
line. Pump bulb an
additional four or five times.
4.
Recoil Starter
Lay the unit on a flat area
and keep movable
attachment parts clear of all
obstacles. Firmly grasp
throttle handle and throttle
trigger lockout with left hand
and fully depress throttle
trigger to wide open
position. Rapidly pull recoil
starter handle (D) until engine fires (or maximum five pulls).
5.
Choke
After engine fires (or five pulls), move choke (B) to the Run (
) (open)
position. Firmly grasp throttle handle and throttle trigger lockout with left
hand and fully depress throttle trigger to wide open position. Pull starter
handle until engine starts and runs. Release throttle trigger and allow unit
to warm up at idle for several minutes.
Note: If engine does not start with choke in “Run” position after five
pulls, repeat instructions 2 - 5.
A
B
C
D